Export limit exceeded: 363290 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 363290 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (363290 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-7890 2 Php, Redhat 3 Php, Enterprise Linux, Rhel Software Collections 2025-04-20 N/A
The GIF decoding function gdImageCreateFromGifCtx in gd_gif_in.c in the GD Graphics Library (aka libgd), as used in PHP before 5.6.31 and 7.x before 7.1.7, does not zero colorMap arrays before use. A specially crafted GIF image could use the uninitialized tables to read ~700 bytes from the top of the stack, potentially disclosing sensitive information.
CVE-2017-7891 1 Sourcebans-pp Project 1 Sourcebans-pp 2025-04-20 N/A
sourcebans-pp (SourceBans++) 1.5.4.7 has XSS in admin.comms.php via the rebanid parameter.
CVE-2017-7892 1 Capnproto 1 Capnproto 2025-04-20 N/A
Sandstorm Cap'n Proto before 0.5.3.1 allows remote crashes related to a compiler optimization. A remote attacker can trigger a segfault in a 32-bit libcapnp application because Cap'n Proto relies on pointer arithmetic calculations that overflow. An example compiler with optimization that elides a bounds check in such calculations is Apple LLVM version 8.1.0 (clang-802.0.41). The attack vector is a crafted far pointer within a message.
CVE-2017-7894 1 Windjview Project 1 Windjview 2025-04-20 N/A
WinDjView 2.1 might allow user-assisted attackers to execute code via a crafted .djvu file, because of a "User Mode Write AV near NULL" in WinDjView.exe. One threat model is a victim who obtains an untrusted .djvu file from a remote location and issues several user-defined commands.
CVE-2017-7895 3 Debian, Linux, Redhat 10 Debian Linux, Linux Kernel, Enterprise Linux and 7 more 2025-04-20 9.8 Critical
The NFSv2 and NFSv3 server implementations in the Linux kernel through 4.10.13 lack certain checks for the end of a buffer, which allows remote attackers to trigger pointer-arithmetic errors or possibly have unspecified other impact via crafted requests, related to fs/nfsd/nfs3xdr.c and fs/nfsd/nfsxdr.c.
CVE-2017-7896 1 Trendmicro 1 Interscan Messaging Security Virtual Appliance 2025-04-20 N/A
Trend Micro InterScan Messaging Security Virtual Appliance (IMSVA) 9.1 before CP 1644 has XSS.
CVE-2017-7897 1 Mantisbt 1 Mantisbt 2025-04-20 N/A
A cross-site scripting (XSS) vulnerability in the MantisBT (2.3.x before 2.3.2) Timeline include page, used in My View (my_view_page.php) and User Information (view_user_page.php) pages, allows remote attackers to inject arbitrary code (if CSP settings permit it) through crafted PATH_INFO in a URL, due to use of unsanitized $_SERVER['PHP_SELF'] to generate URLs.
CVE-2017-7910 1 Digital Canal Structural 1 Wind Analysis 2025-04-20 N/A
A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be able to run arbitrary code by remotely exploiting an executable to perform a denial-of-service attack.
CVE-2017-7899 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2025-04-20 N/A
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.
CVE-2017-7901 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2025-04-20 N/A
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
CVE-2017-7902 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2025-04-20 N/A
A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed.
CVE-2017-7911 1 Cybervision 1 Kaa Iot Platform 2025-04-20 N/A
A Code Injection issue was discovered in CyberVision Kaa IoT Platform, Version 0.7.4. An insufficient-encapsulation vulnerability has been identified, which may allow remote code execution.
CVE-2017-7905 1 Ge 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more 2025-04-20 N/A
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
CVE-2017-7907 1 Schneider-electric 1 Wonderware Historian Client 2025-04-20 N/A
An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.
CVE-2017-7909 1 Advantech B\+b Smartworx 2 Mesr901, Mesr901 Firmware 2025-04-20 N/A
A Use of Client-Side Authentication issue was discovered in Advantech B+B SmartWorx MESR901 firmware versions 1.5.2 and prior. The web interface uses JavaScript to check client authentication and redirect unauthorized users. Attackers may intercept requests and bypass authentication to access restricted web pages.
CVE-2017-7913 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2025-04-20 N/A
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.
CVE-2017-7914 1 Rockwellautomation 2 Panelview Plus 6 700-1500, Panelview Plus 6 700-1500 Firmware 2025-04-20 N/A
A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access.
CVE-2017-7915 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2025-04-20 N/A
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
CVE-2017-7916 1 Abb 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more 2025-04-20 N/A
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
CVE-2017-7917 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2025-04-20 N/A
A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device.