| Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600).
This issue affects Protection and control IED manager (PCM600): through 2.14. |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Protection and control IED manager (PCM600).
This issue affects Protection and control IED manager (PCM600): through 2.14. |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Mint Workbench I.
This issue affects Mint Workbench I: through 5876. |
| Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance Controller AC900.
This issue affects Freelance Controller DCP: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC700: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC800: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1; Freelance Controller AC900: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, and 2019 SP1. |
| Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).
This issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175. |
| Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master.
This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1. |
| Authentication bypass by primary weakness vulnerability in ABB Freelance.
This issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024. |
| Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| Incorrect Authorization vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. |
| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. |
| Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface. |
| A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.
The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.
This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3. |
| ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may
be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst)
This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2. |
| Predictable filename vulnerabilities in ASPECT may expose sensitive information to a potential attacker if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33. |
| DLL's are not digitally signed when loaded in ASPECT's configuration toolset exposing the application to binary planting during device commissioning.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB CoreSense™ HM, ABB CoreSense™ M10.This issue affects CoreSense™ HM: through 2.3.1; CoreSense™ M10: through 1.4.1.12. |
| Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE.
When the REST interface is enabled by the user, and an attacker gains access to
source code and control network, the attacker can bypass the REST interface authentication and gain access to MQTT configuration data.
This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016. |