Export limit exceeded: 367171 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (367171 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-1868 2026-04-15 6.8 Medium
Vulnerability of unauthorized exposure of confidential information affecting Advanced IP Scanner and Advanced Port Scanner. It occurs when these applications initiate a network scan, inadvertently sending the NTLM hash of the user performing the scan. This vulnerability can be exploited by intercepting network traffic to a legitimate server or by setting up a fake server, in both local and remote scenarios. This exposure is relevant for both HTTP/HTTPS and SMB protocols.
CVE-2025-1886 1 Sage 1 Sage 200 Spain 2026-04-15 N/A
Pass-Back vulnerability in versions prior to 2025.35.000 of Sage 200 Spain. This vulnerability allows an authenticated attacker with administrator privileges to discover stored SMTP credentials.
CVE-2025-1883 2026-04-15 7.8 High
Out-Of-Bounds Write vulnerability exists in the OBJ file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025. This vulnerability could allow an attacker to execute arbitrary code while opening a specially crafted OBJ file.
CVE-2025-1884 2026-04-15 7.8 High
Use-After-Free vulnerability exists in the SLDPRT file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025. This vulnerability could allow an attacker to execute arbitrary code while opening a specially crafted SLDPRT file.
CVE-2025-1887 1 Sage 1 Sage 200 Spain 2026-04-15 N/A
SMB forced authentication vulnerability in versions prior to 2025.35.000 of Sage 200 Spain. This vulnerability allows an authenticated attacker with administrator privileges to obtain NTLMv2-SSP Hash by changing any of the paths to a UNC path pointing to a server controlled by the attacker.
CVE-2025-1888 2026-04-15 4.6 Medium
The Leica Web Viewer within the Aperio Eslide Manager Application is vulnerable to reflected cross-site scripting (XSS). An authenticated user can access the slides within a project and injecting malicious JavaScript into the "memo" field. The memo field has a hover over action that will display a Microsoft Tool Tip which a user can use to quickly view the memo associated with the slide and execute the JavaScript.
CVE-2025-31497 2026-04-15 7.5 High
TEIGarage is a webservice and RESTful service to transform, convert and validate various formats, focussing on the TEI format. The Document Conversion Service contains a critical XML External Entity (XXE) Injection vulnerability in its document conversion functionality. The service processes XML files during the conversion process but fails to disable external entity processing, allowing an attacker to read arbitrary files from the server's filesystem. This vulnerability could allow attackers to read sensitive files from the server's filesystem, potentially exposing configuration files, credentials, or other confidential information. Additionally, depending on the server configuration, this could potentially be used to perform server-side request forgery (SSRF) attacks by making the server connect to internal services. This issue is patched in version 1.2.4. A workaround for this vulnerability includes disabling external entity processing in the XML parser by setting the appropriate security features (e.g., XMLConstants.FEATURE_SECURE_PROCESSING).
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2025-32445 1 Argoproj 1 Argo Events 2026-04-15 10 Critical
Argo Events is an event-driven workflow automation framework for Kubernetes. A user with permission to create/modify EventSource and Sensor custom resources can gain privileged access to the host system and cluster, even without having direct administrative privileges. The EventSource and Sensor CRs allow the corresponding orchestrated pod to be customized with spec.template and spec.template.container (with type k8s.io/api/core/v1.Container), thus, any specification under container such as command, args, securityContext , volumeMount can be specified, and applied to the EventSource or Sensor pod. With these, a user would be able to gain privileged access to the cluster host, if he/she specified the EventSource/Sensor CR with some particular properties under template. This vulnerability is fixed in v1.9.6.
CVE-2025-1969 2026-04-15 4.3 Medium
Improper request input validation in Temporary Elevated Access Management (TEAM) for AWS IAM Identity Center allows a user to modify a valid request and spoof an approval in TEAM. Upgrade TEAM to the latest release v.1.2.2. Follow instructions in updating TEAM documentation for updating process
CVE-2025-1974 1 Kubernetes 1 Ingress-nginx 2026-04-15 9.8 Critical
A security issue was discovered in Kubernetes where under certain conditions, an unauthenticated attacker with access to the pod network can achieve arbitrary code execution in the context of the ingress-nginx controller. This can lead to disclosure of Secrets accessible to the controller. (Note that in the default installation, the controller can access all Secrets cluster-wide.)
CVE-2025-1977 1 Moxa 2 Nport 6100-g2 Series, Nport 6200-g2 Series 2026-04-15 N/A
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.
CVE-2025-32776 2026-04-15 5.5 Medium
OpenRazer is an open source driver and user-space daemon to control Razer device lighting and other features on GNU/Linux. By writing specially crafted data to the `matrix_custom_frame` file, an attacker can cause the custom kernel driver to read more bytes than provided by user space. This data will be written into the RGB arguments which will be sent to the USB device. This issue has been patched in v3.10.2.
CVE-2025-24829 2026-04-15 N/A
Local privilege escalation due to DLL hijacking vulnerability. The following products are affected: Acronis Cyber Protect Cloud Agent (Windows) before build 39378.
CVE-2025-1984 2026-04-15 5.2 Medium
Xerox Desktop Print Experience application contains a Local Privilege Escalation (LPE) vulnerability, which allows a low-privileged user to gain SYSTEM-level access.
CVE-2025-1985 2026-04-15 6.1 Medium
Due to improper neutralization of input during web page generation (XSS) an unauthenticated remote attacker can inject HTML code into the Web-UI in the affected device.
CVE-2025-32779 2026-04-15 6.5 Medium
E.D.D.I (Enhanced Dialog Driven Interface) is a middleware to connect and manage LLM API bots. In versions before 5.5.0, an attacker with access to the `/backup/import` API endpoint can write arbitrary files to locations outside the intended extraction directory due to a Zip Slip vulnerability. Although the application runs as a non-root user (`185`), limiting direct impact on system-level files, this vulnerability can still be exploited to overwrite application files (e.g., JAR libraries) owned by the application user. This overwrite can potentially lead to Remote Code Execution (RCE) within the application's context. This issue has been patched in version 5.5.0.
CVE-2025-20002 2026-04-15 5.3 Medium
After attempting to upload a file that does not meet prerequisites, GMOD Apollo will respond with local path information disclosure
CVE-2025-20003 2026-04-15 8.2 High
Improper link resolution before file access ('Link Following') for some Intel(R) Graphics Driver software installers may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-20004 2026-04-15 7.2 High
Insufficient control flow management in the Alias Checking Trusted Module for some Intel(R) Xeon(R) 6 processor E-Cores firmware may allow a privileged user to potentially enable escalation of privilege via local access.