Export limit exceeded: 369522 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (369522 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-57423 | 1 Myclub | 1 Myclub | 2026-04-15 | 6.5 Medium |
| A SQL injection vulnerability was discovered in the /articles endpoint of MyClub 0.5, affecting the query parameters Content, GroupName, PersonName, lastUpdate, pool, and title. Due to insufficient input sanitisation, an unauthenticated remote attacker could inject arbitrary SQL commands via a crafted GET request, potentially leading to information disclosure or manipulation of the database. | ||||
| CVE-2025-57424 | 1 Hbi | 1 Mycourts | 2026-04-15 | 7.3 High |
| A stored cross-site scripting (XSS) vulnerability exists in the MyCourts v3 application within the LTA number profile field. An attacker can insert arbitrary JavaScript into their profile, which executes in the browser of any user viewing it, including administrators. Due to the absence of the HttpOnly flag on the session cookie, this flaw could be exploited to capture session tokens and hijack user sessions, enabling elevated access. | ||||
| CVE-2025-57428 | 1 Each Italy | 1 Wireless Mini Router | 2026-04-15 | 6.5 Medium |
| Default credentials in Each Italy Wireless Mini Router WIRELESS-N 300M v28K.MiniRouter.20190211 allows attackers to gain access to the debug shell exposed via Telnet on Port 23 and execute hardware-level flash and register manipulation commands. | ||||
| CVE-2025-5743 | 2026-04-15 | 5.5 Medium | ||
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated user modifies configuration parameters on the web server. | ||||
| CVE-2025-57440 | 1 Blackmagic | 1 Atem Mini Pro | 2026-04-15 | 7.5 High |
| The Blackmagic ATEM Mini Pro 2.7 exposes an undocumented Telnet service on TCP port 9993, which accepts unauthenticated plaintext commands for controlling streaming, recording, formatting storage devices, and system reboot. This interface, referred to as the "ATEM Ethernet Protocol 1.0", provides complete device control without requiring credentials or encryption. An attacker on the same network (or with remote access to the exposed port) can exploit this interface to execute arbitrary streaming commands, erase disks, or shut down the device - effectively gaining full remote control. | ||||
| CVE-2025-57443 | 2 Apple, Frostwire | 2 Macos, Frostwire | 2026-04-15 | 5.1 Medium |
| FrostWire 6.14.0-build-326 for macOS contains permissive entitlements (allow-dyld-environment-variables, disable-library-validation) that allow unprivileged local attackers to inject code into the FrostWire process via the DYLD_INSERT_LIBRARIES environment variable. This allows escalated privileges to arbitrary TCC-approved directories. | ||||
| CVE-2025-57444 | 1 Radware | 1 Alteonos | 2026-04-15 | 6.1 Medium |
| An authenticated cross-site scripting (XSS) vulnerability in the Administrative interface of Radware AlteonOS Web UI Management v33.0.4.50 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the Description parameter. | ||||
| CVE-2025-57446 | 1 O-ran-sc | 1 Ric-plt-submgr | 2026-04-15 | 7.5 High |
| An issue in O-RAN Near Realtime RIC ric-plt-submgr in the J-Release environment, allows remote attackers to cause a denial of service (DoS) via a crafted request to the Subscription Manager API component. | ||||
| CVE-2025-57483 | 1 Tawk | 1 Tawk.to | 2026-04-15 | 8.1 High |
| A reflected cross-site scripting (XSS) vulnerability in tawk.to chatbox widget v4 allows attackers to execute arbitrary Javascript in the context of the user's browser via injecting a crafted payload into the vulnerable parameter. | ||||
| CVE-2025-57563 | 1 Starnet | 1 Fastx | 2026-04-15 | 6.5 Medium |
| A path traversal in StarNet Communications Corporation FastX v.4 through v4.1.51 allows unauthenticated attackers to read arbitrary files. | ||||
| CVE-2025-57577 | 1 H3c | 1 R365v300r004 | 2026-04-15 | 8 High |
| An issue in H3C Device R365V300R004 allows a remote attacker to execute arbitrary code via the default password. NOTE: the Supplier's position is that their "product lines enforce or clearly prompt users to change any initial credentials upon first use. At most, this would be a case of misconfiguration if an administrator deliberately ignored the prompts, which is outside the scope of CVE definitions." | ||||
| CVE-2025-57578 | 1 H3c | 1 Magic | 2026-04-15 | 8 High |
| An issue in H3C Magic M Device M2V100R006 allows a remote attacker to execute arbitrary code via the default password | ||||
| CVE-2025-57601 | 1 Aikaan | 1 Cloud Controller | 2026-04-15 | 9.8 Critical |
| AiKaan Cloud Controller uses a single hardcoded SSH private key and the username `proxyuser` for remote terminal access to all managed IoT/edge devices. When an administrator initiates "Open Remote Terminal" from the AiKaan dashboard, the controller sends this same static private key to the target device. The device then uses it to establish a reverse SSH tunnel to a remote access server, enabling browser-based SSH access for the administrator. Because the same `proxyuser` account and SSH key are reused across all customer environments: - An attacker who obtains the key (e.g., by intercepting it in transit, extracting it from the remote access server, or from a compromised admin account) can impersonate any managed device. - They can establish unauthorized reverse SSH tunnels and interact with devices without the owner's consent. This is a design flaw in the authentication model: compromise of a single key compromises the trust boundary between the controller and devices. | ||||
| CVE-2025-57602 | 1 Aikaan | 1 Iot Management Platform | 2026-04-15 | 9.8 Critical |
| Insufficient hardening of the proxyuser account in the AiKaan IoT management platform, combined with the use of a shared, hardcoded SSH private key, allows remote attackers to authenticate to the cloud controller, gain interactive shell access, and pivot into other connected IoT devices. This can lead to remote code execution, information disclosure, and privilege escalation across customer environments. | ||||
| CVE-2025-57605 | 1 Aikaan | 1 Iot Platform | 2026-04-15 | 8.8 High |
| Lack of server-side authorisation on department admin assignment APIs in AiKaan IoT Platform allows authenticated users to elevate their privileges by assigning themselves as admins of other departments. This results in unauthorized privilege escalation across the department | ||||
| CVE-2025-57624 | 2026-04-15 | 7.8 High | ||
| A DLL hijacking vulnerability in CYRISMA Agent before 444 allows local users to escalate privileges and execute arbitrary code via multiple DLLs. | ||||
| CVE-2025-57625 | 1 Microsoft | 1 Windows | 2026-04-15 | 8.8 High |
| CYRISMA Sensor before 444 for Windows has an Insecure Folder and File Permissions vulnerability. A low-privileged user can abuse these issues to escalate privileges and execute arbitrary code in the context of NT AUTHORITY\SYSTEM by replacing DataSpotliteAgent.exe or any other binaries called by the Cyrisma_Agent service when it starts | ||||
| CVE-2025-57632 | 2026-04-15 | 7.5 High | ||
| libsmb2 6.2+ is vulnerable to Buffer Overflow. When processing SMB2 chained PDUs (NextCommand), libsmb2 repeatedly calls smb2_add_iovector() to append to a fixed-size iovec array without checking the upper bound of v->niov (SMB2_MAX_VECTORS=256). An attacker can craft responses with many chained PDUs to overflow v->niov and perform heap out-of-bounds writes, causing memory corruption, crashes, and potentially arbitrary code execution. The SMB2_OPLOCK_BREAK path bypasses message ID validation. | ||||
| CVE-2025-57633 | 2026-04-15 | 9.8 Critical | ||
| A command injection vulnerability in FTP-Flask-python through 5173b68 allows unauthenticated remote attackers to execute arbitrary OS commands. The /ftp.html endpoint's "Upload File" action constructs a shell command from the ftp_file parameter and executes it using os.system() without sanitization or escaping. | ||||
| CVE-2025-57685 | 1 B-link | 7 Bl-ac1900, Bl-ac2100 Az3, Bl-wr9000 and 4 more | 2026-04-15 | 8.8 High |
| The LB-Link routers, including the BL-AC2100_AZ3 V1.0.4, BL-WR4000 v2.5.0, BL-WR9000_AE4 v2.4.9, BL-AC1900_AZ2 v1.0.2, BL-X26_AC8 v1.2.8, and BL-LTE300_DA4 V1.2.3 models, are vulnerable to unauthorized command injection. Attackers can exploit this vulnerability by accessing the /goform/set_serial_cfg interface to gain the highest level of device privileges without authorization, enabling them to remotely execute malicious commands. | ||||