Export limit exceeded: 384591 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (384591 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-31724 | 1 Yasm Project | 1 Yasm | 2025-01-22 | 7.8 High |
| yasm 1.3.0.55.g101bc was discovered to contain a segmentation violation via the function do_directive at /nasm/nasm-pp.c. | ||||
| CVE-2023-31723 | 1 Yasm Project | 1 Yasm | 2025-01-22 | 5.5 Medium |
| yasm 1.3.0.55.g101bc was discovered to contain a segmentation violation via the function expand_mmac_params at /nasm/nasm-pp.c. | ||||
| CVE-2023-29985 | 1 Oretnom23 | 1 Student Study Center Desk Management System | 2025-01-22 | 9.8 Critical |
| Sourcecodester Student Study Center Desk Management System v1.0 admin\reports\index.php#date_from has a SQL Injection vulnerability. | ||||
| CVE-2023-28369 | 1 Brother | 1 Iprint\&scan | 2025-01-22 | 3.3 Low |
| Brother iPrint&Scan V6.11.2 and earlier contains an improper access control vulnerability. This vulnerability may be exploited by the other app installed on the victim user's Android device, which may lead to displaying the settings and/or log information of the affected app as a print preview. | ||||
| CVE-2023-27217 | 1 Belkin | 2 F7c063, F7c063 Firmware | 2025-01-22 | 9.8 Critical |
| A stack-based buffer overflow in the ChangeFriendlyName() function of Belkin Smart Outlet V2 F7c063 firmware_2.00.11420.OWRT.PVT_SNSV2 allows attackers to cause a Denial of Service (DoS) via a crafted UPNP request. | ||||
| CVE-2019-25137 | 1 Umbraco | 1 Umbraco Cms | 2025-01-22 | 7.2 High |
| Umbraco CMS 4.11.8 through 7.15.10, and 7.12.4, allows Remote Code Execution by authenticated administrators via msxsl:script in an xsltSelection to developer/Xslt/xsltVisualize.aspx. | ||||
| CVE-2023-5779 | 1 Zephyrproject | 1 Zephyr | 2025-01-22 | 4.4 Medium |
| can: out of bounds in remove_rx_filter function | ||||
| CVE-2023-6749 | 1 Zephyrproject | 1 Zephyr | 2025-01-22 | 8 High |
| Unchecked length coming from user input in settings shell | ||||
| CVE-2022-42443 | 1 Ibm | 2 Trusteer Android Sdk For Mobile, Trusteer Ios Sdk For Mobile | 2025-01-22 | 2.2 Low |
| An undisclosed issue in Trusteer iOS SDK for mobile versions prior to 5.7 and Trusteer Android SDK for mobile versions prior to 5.7 may allow uploading of files. IBM X-Force ID: 238535. | ||||
| CVE-2023-2509 | 1 Asustor | 3 Adm, Looksgood, Soundsgood | 2025-01-22 | 7.1 High |
| A Cross-Site Scripting(XSS) vulnerability was found on ADM, LooksGood and SoundsGood Apps. An attacker can exploit this vulnerability to inject malicious scripts into the target applications to access any cookies or sensitive information retained by the browser and used with that application. Affected products and versions include: ADM 4.0.6.REG2, 4.1.0 and below as well as ADM 4.2.1.RGE2 and below, LooksGood 2.0.0.R129 and below and SoundsGood 2.3.0.r1027 and below. | ||||
| CVE-2023-0863 | 1 Abb | 16 Terra Ac Wallbox 80a, Terra Ac Wallbox 80a Firmware, Terra Ac Wallbox Ce Juno and 13 more | 2025-01-22 | 8.8 High |
| Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5. | ||||
| CVE-2023-0864 | 1 Abb | 16 Terra Ac Wallbox 80a, Terra Ac Wallbox 80a Firmware, Terra Ac Wallbox Ce Juno and 13 more | 2025-01-22 | 7.1 High |
| Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5. | ||||
| CVE-2023-30438 | 1 Ibm | 17 Power System E1050, Power System E1080, Power System E950 and 14 more | 2025-01-22 | 9.3 Critical |
| An internally discovered vulnerability in PowerVM on IBM Power9 and Power10 systems could allow an attacker with privileged user access to a logical partition to perform an undetected violation of the isolation between logical partitions which could lead to data leakage or the execution of arbitrary code in other logical partitions on the same physical server. IBM X-Force ID: 252706. | ||||
| CVE-2023-22348 | 2 Checkmk, Tribe29 | 2 Checkmk, Checkmk | 2025-01-22 | 4.3 Medium |
| Improper Authorization in RestAPI in Checkmk GmbH's Checkmk versions <2.1.0p28 and <2.2.0b8 allows remote authenticated users to read arbitrary host_configs. | ||||
| CVE-2023-31135 | 1 Dgraph | 1 Dgraph | 2025-01-22 | 3.3 Low |
| Dgraph is an open source distributed GraphQL database. Existing Dgraph audit logs are vulnerable to brute force attacks due to nonce collisions. The first 12 bytes come from a baseIv which is initialized when an audit log is created. The last 4 bytes come from the length of the log line being encrypted. This is problematic because two log lines will often have the same length, so due to these collisions we are reusing the same nonce many times. All audit logs generated by versions of Dgraph <v23.0.0 are affected. Attackers must have access to the system the logs are stored on. Dgraph users should upgrade to v23.0.0. Users unable to upgrade should store existing audit logs in a secure location and for extra security, encrypt using an external tool like `gpg`. | ||||
| CVE-2022-45459 | 2 Acronis, Microsoft | 3 Agent, Cyber Protect, Windows | 2025-01-22 | 7.5 High |
| Sensitive information disclosure due to insecure registry permissions. The following products are affected: Acronis Agent (Windows) before build 30025, Acronis Cyber Protect 15 (Windows) before build 30984. | ||||
| CVE-2022-45450 | 4 Acronis, Apple, Linux and 1 more | 5 Agent, Cyber Protect, Macos and 2 more | 2025-01-22 | 7.5 High |
| Sensitive information disclosure and manipulation due to improper authorization. The following products are affected: Acronis Agent (Linux, macOS, Windows) before build 28610, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 30984. | ||||
| CVE-2022-4418 | 2 Acronis, Microsoft | 2 Cyber Protect Home Office, Windows | 2025-01-22 | 7.8 High |
| Local privilege escalation due to unrestricted loading of unsigned libraries. The following products are affected: Acronis Cyber Protect Home Office (Windows) before build 40208. | ||||
| CVE-2022-32427 | 1 Printerlogic | 1 Windows Client | 2025-01-22 | 8.8 High |
| PrinterLogic Windows Client through 25.0.0.676 allows attackers to execute directory traversal. Authenticated users with prior knowledge of the driver filename could exploit this to escalate privileges or distribute malicious content. This issue has been resolved in PrinterLogic Windows Client 25.0.0688 and all affected are advised to upgrade. | ||||
| CVE-2023-2782 | 1 Acronis | 1 Cyber Infrastructure | 2025-01-22 | 5.5 Medium |
| Sensitive information disclosure due to improper authorization. The following products are affected: Acronis Cyber Infrastructure (ACI) before build 5.3.1-38. | ||||