Export limit exceeded: 387039 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (387039 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-6031 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2025-04-20 | N/A |
| A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution. | ||||
| CVE-2017-6029 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2025-04-20 | N/A |
| A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution. | ||||
| CVE-2017-6025 | 1 Codesys | 1 Web Server | 2025-04-20 | N/A |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. | ||||
| CVE-2017-6022 | 1 Bd | 2 Kla Journal Service, Performa | 2025-04-20 | N/A |
| A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. | ||||
| CVE-2017-6019 | 1 Schneider-electric | 2 Conext Combox 865-1058, Conext Combox 865-1058 Firmware | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot. | ||||
| CVE-2017-6018 | 1 Bbraun | 2 Spacestation, Station Firmware | 2025-04-20 | N/A |
| An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input. | ||||
| CVE-2016-10024 | 2 Citrix, Xen | 2 Xenserver, Xen | 2025-04-20 | N/A |
| Xen through 4.8.x allows local x86 PV guest OS kernel administrators to cause a denial of service (host hang or crash) by modifying the instruction stream asynchronously while performing certain kernel operations. | ||||
| CVE-2017-9932 | 1 Greenpacket | 2 Dx-350, Dx-350 Firmware | 2025-04-20 | N/A |
| Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account. | ||||
| CVE-2017-6017 | 1 Schneider-electric | 30 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 27 more | 2025-04-20 | N/A |
| A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. | ||||
| CVE-2017-9927 | 2 Microsoft, Swftools | 2 Windows, Swftools | 2025-04-20 | N/A |
| In SWFTools 2013-04-09-1007 on Windows, png2swf allows remote attackers to cause a denial of service or possibly have unspecified other impact via a crafted file, related to a "Read Access Violation starting at image00000000_00400000+0x000000000001b5fe." | ||||
| CVE-2017-6016 | 1 Leao Consultoria E Desenvolvimento De Sistemas | 1 Ltda Me Laquis Scada | 2025-04-20 | N/A |
| An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges. | ||||
| CVE-2017-9926 | 2 Microsoft, Swftools | 2 Windows, Swftools | 2025-04-20 | N/A |
| In SWFTools 2013-04-09-1007 on Windows, png2swf allows remote attackers to cause a denial of service or possibly have unspecified other impact via a crafted file, related to a "Read Access Violation starting at image00000000_00400000+0x000000000001b596." | ||||
| CVE-2017-6014 | 2 Debian, Wireshark | 2 Debian Linux, Wireshark | 2025-04-20 | N/A |
| In Wireshark 2.2.4 and earlier, a crafted or malformed STANAG 4607 capture file will cause an infinite loop and memory exhaustion. If the packet size field in a packet header is null, the offset to read from will not advance, causing continuous attempts to read the same zero length packet. This will quickly exhaust all system memory. | ||||
| CVE-2017-6011 | 3 Debian, Icoutils Project, Redhat | 9 Debian Linux, Icoutils, Enterprise Linux and 6 more | 2025-04-20 | N/A |
| An issue was discovered in icoutils 0.31.1. An out-of-bounds read leading to a buffer overflow was observed in the "simple_vec" function in the "extract.c" source file. This affects icotool. | ||||
| CVE-2017-6010 | 3 Debian, Icoutils Project, Redhat | 9 Debian Linux, Icoutils, Enterprise Linux and 6 more | 2025-04-20 | N/A |
| An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "extract_icons" function in the "extract.c" source file. This issue can be triggered by processing a corrupted ico file and will result in an icotool crash. | ||||
| CVE-2017-6009 | 3 Debian, Icoutils Project, Redhat | 9 Debian Linux, Icoutils, Enterprise Linux and 6 more | 2025-04-20 | N/A |
| An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "decode_ne_resource_id" function in the "restable.c" source file. This is happening because the "len" parameter for memcpy is not checked for size and thus becomes a negative integer in the process, resulting in a failed memcpy. This affects wrestool. | ||||
| CVE-2017-9924 | 2 Microsoft, Swftools | 2 Windows, Swftools | 2025-04-20 | N/A |
| In SWFTools 2013-04-09-1007 on Windows, png2swf allows remote attackers to execute arbitrary code or cause a denial of service via a crafted file, related to a "User Mode Write AV starting at image00000000_00400000+0x000000000001b72a." | ||||
| CVE-2017-9923 | 1 Irfanview | 2 Irfanview, Tools | 2025-04-20 | N/A |
| IrfanView version 4.44 (32bit) with TOOLS Plugin 4.50 might allow attackers to cause a denial of service or execute arbitrary code via a crafted file, related to "Data from Faulting Address controls Branch Selection starting at KERNELBASE!EnumResourceTypesInternal+0x0000000000000589." | ||||
| CVE-2013-6465 | 1 Redhat | 1 Jbpm | 2025-04-20 | N/A |
| Multiple cross-site scripting (XSS) vulnerabilities in JBPM KIE Workbench 6.0.x allow remote authenticated users to inject arbitrary web script or HTML via vectors related to task name html inputs. | ||||
| CVE-2017-9922 | 1 Irfanview | 2 Irfanview, Tools | 2025-04-20 | N/A |
| IrfanView version 4.44 (32bit) with TOOLS Plugin 4.50 might allow attackers to cause a denial of service or execute arbitrary code via a crafted file, related to "Data from Faulting Address controls Branch Selection starting at ntdll_77df0000!LdrpCompareResourceNames_U+0x0000000000000062." | ||||