Description
A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formLogin of the file /boaform/formLogin of the component Boa Web Server. Executing a manipulation of the argument Username can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
Published: 2026-09-03
Score: 9.3 Critical
EPSS: n/a
KEV: No
Impact: n/a
Action: n/a
AI Analysis

Analysis and contextual insights are available on OpenCVE Cloud.

Remediation

No vendor fix or workaround currently provided.

Additional remediation guidance may be available on OpenCVE Cloud.

Tracking

Sign in to view the affected projects.

Advisories

No advisories yet.

History

Thu, 03 Sep 2026 15:30:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Thu, 03 Sep 2026 15:00:00 +0000

Type Values Removed Values Added
First Time appeared Tenda hg10
Vendors & Products Tenda hg10

Thu, 03 Sep 2026 13:45:00 +0000

Type Values Removed Values Added
Description A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formLogin of the file /boaform/formLogin of the component Boa Web Server. Executing a manipulation of the argument Username can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
Title Tenda HG10 Boa Web Server formLogin buffer overflow
First Time appeared Tenda
Tenda hg10 Firmware
Weaknesses CWE-119
CWE-120
CPEs cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
Vendors & Products Tenda
Tenda hg10 Firmware
References
Metrics cvssV2_0

{'score': 10, 'vector': 'AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR'}

cvssV3_0

{'score': 9.8, 'vector': 'CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R'}

cvssV3_1

{'score': 9.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R'}

cvssV4_0

{'score': 9.3, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P'}


Subscriptions

Tenda Hg10 Hg10 Firmware
cve-icon MITRE

Status: PUBLISHED

Assigner: VulDB

Published:

Updated: 2026-09-03T14:29:53.673Z

Reserved: 2026-09-03T06:53:31.120Z

Link: CVE-2026-85109

cve-icon Vulnrichment

Updated: 2026-09-03T14:15:24.863Z

cve-icon NVD

Status : Deferred

Published: 2026-09-03T14:17:04.663

Modified: 2026-09-03T17:25:25.113

Link: CVE-2026-85109

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-09-03T15:00:06Z

Weaknesses