| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Citizens Community Bank (TN) ccb-mobile-banking/id610030469 app 3.0.1 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. |
| The North Adams State Bank (Ursa) nasb-mobile-banking/id980573797 app 3.0.1 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. |
| The "KC Area Credit Union Mobile Banking" by K C Area Credit Union app 3.0.1 -- aka kc-area-credit-union-mobile-banking/id1097607736 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. |
| The "First Citizens Bank-Mobile Banking" by First Citizens Bank (AL) app 3.0.0 -- aka first-citizens-bank-mobile-banking/id566037101 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. |
| The "Blue Ridge Bank and Trust Co. Mobile Banking" by Blue Ridge Bank and Trust Co. app 3.0.1 -- aka blue-ridge-bank-and-trust-co-mobile-banking/id699679197 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. |
| The "Peoples Bank Tulsa" by Peoples Bank - OK app 3.0.2 -- aka peoples-bank-tulsa/id1074279285 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. |
| KDE kmail before 5.5.2 and messagelib before 5.5.2, as distributed in KDE Applications before 17.04.2, do not ensure that a plugin's sign/encrypt action occurs during use of the Send Later feature, which allows remote attackers to obtain sensitive information by sniffing the network. |
| Stored Cross-site scripting (XSS) vulnerability in SAP SuccessFactors before b1705.1234962 allows remote authenticated users to inject arbitrary web script or HTML via the file upload functionality. |
| The xps_load_sfnt_name function in xps/xpsfont.c in Artifex Ghostscript GhostXPS 9.21 allows remote attackers to cause a denial of service (buffer overflow and application crash) or possibly have unspecified other impact via a crafted document. |
| An Information Exposure issue was discovered in Saia Burgess Controls PCD Controllers with PCD firmware versions prior to 1.28.16 or 1.24.69. In certain circumstances, the device pads Ethernet frames with memory contents. |
| A Missing Encryption of Sensitive Data issue was discovered in PDQ Manufacturing LaserWash G5 and G5 S Series all versions, LaserWash M5, all versions, LaserWash 360 and 360 Plus, all versions, LaserWash AutoXpress and AutoExpress Plus, all versions, LaserJet, all versions, ProTouch Tandem, all versions, ProTouch ICON, all versions, and ProTouch AutoGloss, all versions. The username and password are transmitted insecurely. |
| A Path Traversal issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web prior to 6.5; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to overwrite files that are used to execute code. This vulnerability does not affect version 6.5 of the software. |
| An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level. |
| A Stack-Based Buffer Overflow issue was discovered in the Continental AG Infineon S-Gold 2 (PMB 8876) chipset on BMW several models produced between 2009-2010, Ford a limited number of P-HEV vehicles, Infiniti 2013 JX35, Infiniti 2014-2016 QX60, Infiniti 2014-2016 QX60 Hybrid, Infiniti 2014-2015 QX50, Infiniti 2014-2015 QX50 Hybrid, Infiniti 2013 M37/M56, Infiniti 2014-2016 Q70, Infiniti 2014-2016 Q70L, Infiniti 2015-2016 Q70 Hybrid, Infiniti 2013 QX56, Infiniti 2014-2016 QX 80, and Nissan 2011-2015 Leaf. An attacker with a physical connection to the TCU may exploit a buffer overflow condition that exists in the processing of AT commands. This may allow arbitrary code execution on the baseband radio processor of the TCU. |
| A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device. |
| A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed. |
| An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication. |
| A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device. |
| An Improper Access Control issue was discovered in Cambium Networks ePMP. After a valid user has used SNMP configuration export, an attacker is able to remotely trigger device configuration backups using specific MIBs. These backups lack proper access control and may allow access to sensitive information and possibly allow for configuration changes. |
| An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating. |