| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| A vulnerability was found in Apeman ID71 218.53.203.117. The impacted element is an unknown function of the file /onvif/device_service of the component ONVIF Service. Performing manipulation results in missing authentication. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Incorrect access control in the component l_0_0.xml of TP-Link ARCHER-C7 v5 allows attackers to access sensitive information. |
| An issue in Quectel BC95-CNV V100R001C00SPC051 allows attackers to bypass authentication via a crafted NAS message. |
| An issue in Quectel BG96 BG96MAR02A08M1G allows attackers to bypass authentication via a crafted NAS message. NOTE: this is disputed by the supplier. |
| Server-Side Access Control Bypass vulnerability in WombatDialer before 25.02 could allow unauthorized users to potentially call certain services without the necessary access level. This issue is limited to services used by the client (not the general-use JSON services) and requires reverse engineering of the proprietary serialization protocol, making it difficult to exploit. |
| A remote unauthenticated attacker may be able to bypass authentication
by utilizing a specific API route to execute arbitrary OS commands. |
| The airPASS from NetVision Information has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access the specific administrative functionality to retrieve * all accounts and passwords. |
| Statistical Database System developed by Gotac has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents with high-level privileges. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .Â
All firmware versions with the Serial Number from 2000 to 5166 |
| A remote code execution vulnerability exists in HybridAuth versions 2.0.9 through 2.2.2 due to insecure use of the install.php installation script. The script remains accessible after deployment and fails to sanitize input before writing to the application’s config.php file. An unauthenticated attacker can inject arbitrary PHP code into config.php, which is later executed when the file is loaded. This allows attackers to achieve remote code execution on the server. Exploitation of this issue will overwrite the existing configuration, rendering the application non-functional. |
| A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset.
Affected Products:
UniFi Connect EV Station Pro (Version 1.5.18 and earlier)
Mitigation:
Update UniFi Connect EV Station Pro to Version 1.5.27 or later |
| The system exposes several endpoints, typically including "/int/" in their path, that should be restricted to internal services, but are instead publicly accessible without authentication to any host able to reach the application server on port 443/tcp. |
| Unauthenticated access to the "/cgi-bin/CliniNET.prd/GetActiveSessions.pl" endpoint allows takeover of any user session logged into the system, including users with admin privileges. |
| The vulnerability allows unauthenticated users to download a file containing session ID data by directly accessing the "/cgi-bin/CliniNET.prd/utils/userlogxls.pl" endpoint. |
| The paths "/cgi-bin/CliniNET.prd/utils/userlogstat.pl", "/cgi-bin/CliniNET.prd/utils/usrlogstat.pl", and "/cgi-bin/CliniNET.prd/utils/dblogstat.pl" expose data containing session IDs. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. Via port 7777 without any need to pair or press a physical button, a remote attacker can disable recording, delete recordings, or even disable battery protection to cause a flat battery to essentially disable the car from being used. During the process of changing these settings, there are no indications or sounds on the dashcam to alert the dashcam owner that someone else is making those changes. |
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. |