| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval. |
| A Code Injection issue was discovered in CyberVision Kaa IoT Platform, Version 0.7.4. An insufficient-encapsulation vulnerability has been identified, which may allow remote code execution. |
| A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed. |
| An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network. |
| A Use of Client-Side Authentication issue was discovered in Advantech B+B SmartWorx MESR901 firmware versions 1.5.2 and prior. The web interface uses JavaScript to check client authentication and redirect unauthorized users. Attackers may intercept requests and bypass authentication to access restricted web pages. |
| A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access. |
| An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication. |
| A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted. |
| An Improper Access Control issue was discovered in Cambium Networks ePMP. After a valid user has used SNMP configuration export, an attacker is able to remotely trigger device configuration backups using specific MIBs. These backups lack proper access control and may allow access to sensitive information and possibly allow for configuration changes. |
| An Improper Authentication issue was discovered in Newport XPS-Cx and XPS-Qx. An attacker may bypass authentication by accessing a specific uniform resource locator (URL). |
| An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating. |
| WonderCMS before 2.0.3 has CSRF because of lack of a token in an unspecified context. |
| An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands (PCCC) packet to the controller that could potentially cause the controller to enter a DoS condition. |
| A Cross-Site Request Forgery issue was discovered in OSIsoft PI Web API versions prior to 2017 (1.9.0). The vulnerability allows cross-site request forgery (CSRF) attacks to occur when an otherwise-unauthorized cross-site request is sent from a browser the server has previously authenticated. |
| INFOR EAM V11.0 Build 201410 has XSS via comment fields. |
| An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may allow for unauthorized communications to downstream devices. |
| An Absolute Path Traversal issue was discovered in Advantech WebAccess Version 8.1 and prior. The absolute path traversal vulnerability has been identified, which may allow an attacker to traverse the file system to access restricted files or directories. |
| An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Data Archive has protocol flaws with the potential to expose change records in the clear and allow a malicious party to spoof a server within a collective. |
| A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device's availability by performing multiple initial VPN requests. |
| An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may be able to gain unauthorized access to the user firewall when RADIUS servers are unreachable. |