| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| General Bytes Crypto Application Server (CAS) beginning with version 20201208 prior to 20220531.38 (backport) and 20220725.22 (mainline) contains an authentication bypass in the admin web interface. An unauthenticated attacker could invoke the same URL used by the product's default-installation / first-admin creation page and create a new administrative account remotely. By gaining admin privileges, the attacker can change the ATM configuration resulting in redirected funds. Public vendor advisories and multiple independent writeups describe the vulnerability as a call to the page used for initial/default installation / first administration user creation; General Bytes has not publicly published the exact endpoint/parameter name. The issue was actively exploited in the wild against cloud-hosted and standalone CAS deployments (scanning exposed CAS instances on ports 7777/443), and publicly acknowledged by the General Bytes in September 2022. |
| A vulnerability was found in whuan132 AIBattery up to 1.0.9. The affected element is an unknown function of the file AIBatteryHelper/XPC/BatteryXPCService.swift of the component com.collweb.AIBatteryHelper. The manipulation results in missing authentication. The attack requires a local approach. The exploit has been made public and could be used. |
| A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future. |
| Missing authentication for critical function vulnerability exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote unauthenticated attacker may update or downgrade the firmware on the device. |
| A command injection vulnerability exists in the eScan Web Management Console version 5.5-2. The application fails to properly sanitize the 'pass' parameter when processing login requests to login.php, allowing an authenticated attacker with a valid username to inject arbitrary commands via a specially crafted password value. Successful exploitation results in remote code execution. Privilege escalation to root is possible by abusing the runasroot utility with mwconf-level privileges. |
| An unauthenticated remote attacker can run arbitrary commands on the affected devices with high privileges because the authentication for the Node_RED server is not configured by default. |
| An issue was discovered in TitanHQ SpamTitan Email Security Gateway 8.00.x before 8.00.101 and 8.01.x before 8.01.14. The file quarantine.php within the SpamTitan interface allows unauthenticated users to trigger account-level actions using a crafted GET request. Notably, when a non-existent email address is provided as part of the email parameter, SpamTitan will automatically create a user record and associate quarantine settings with it - all without requiring authentication. |
| TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents. |
| Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username |
| OMNTEC Proteus Tank Monitoring OEL8000III Series
could allow an attacker to perform administrative actions without proper authentication. |
| The Linux Kernel lockdown mode for kernel versions starting on 6.12 and above for Fedora Linux has the lockdown mode disabled without any warning. This may allow an attacker to gain access to sensitive information such kernel memory mappings, I/O ports, BPF and kprobes. Additionally unsigned modules can be loaded, leading to execution of untrusted code breaking breaking any Secure Boot protection. This vulnerability affects only Fedora Linux. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| The health module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| Traq versions 2.0 through 2.3 contain a remote code execution vulnerability in the admincp/common.php script. The flawed authorization logic fails to halt execution after a failed access check, allowing unauthenticated users to reach admin-only functionality. This can be exploited via plugins.php to inject and execute arbitrary PHP code. |
| Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information. |