| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. |
|
Franklin Fueling System EVO 550 and EVO 5000 are vulnerable to a Path Traversal vulnerability that could allow an attacker to access sensitive files on the system.
|
| Amazon EMR Secret Agent creates a keytab file containing Kerberos credentials. This file is stored in the /tmp/ directory. A user with access to this directory and another account can potentially decrypt the keys and escalate to higher privileges.
Users are advised to upgrade to Amazon EMR version 7.5 or higher. For Amazon EMR releases between 6.10 and 7.4, we strongly recommend that you run the bootstrap script and RPM files with the fix provided in the location below. |
| An attacker could decrypt sensitive data, impersonate legitimate users
or devices, and potentially gain access to network resources for lateral
attacks. |
| A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been classified as problematic. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to store passwords in cleartext. |
| NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer when the driver is performing an operation at a privilege level that is higher than the minimum level required. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering. |
| Weak password storage vulnerabilities exist in ASPECT if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system. |
| Unitronics Vision Standard line of controllers allow the Information Mode password to be retrieved without authentication. |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
|
In AutomationDirect C-MORE EA9 HMI,
credentials used by the platform are stored as plain text on the device.
|
| LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs. |
| Incorrect Access Control vulnerability in ZLMediaKit versions 1.0 through 8.0, allows remote attackers to escalate privileges and obtain sensitive information. The application system enables the http API interface by default and uses the secret parameter method to authenticate the http restful api interface, but the secret is hardcoded by default. |
| Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network. |
| A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance. |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
The affected models are out of support; replacing the device is recommended. |
| A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state. |