Search

Search Results (387294 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-9176 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 allows remote attackers to cause a denial of service (invalid write and SEGV), related to the ReadImage function in input-bmp.c:370:25.
CVE-2017-9169 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 has a heap-based buffer overflow in the ReadImage function in input-bmp.c:355:25.
CVE-2017-9170 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 has a heap-based buffer overflow in the ReadImage function in input-bmp.c:370:25.
CVE-2017-9171 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 has a heap-based buffer over-read in the ReadImage function in input-bmp.c:492:24.
CVE-2017-9172 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 has a heap-based buffer overflow in the ReadImage function in input-bmp.c:496:29.
CVE-2017-9177 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 allows remote attackers to cause a denial of service (invalid read and SEGV), related to the ReadImage function in input-bmp.c:390:12.
CVE-2017-9173 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 has a heap-based buffer overflow in the ReadImage function in input-bmp.c:497:29.
CVE-2017-9174 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 allows remote attackers to cause a denial of service (invalid read and SEGV), related to the GET_COLOR function in color.c:21:23.
CVE-2017-9175 1 Autotrace Project 1 Autotrace 2025-04-20 N/A
libautotrace.a in AutoTrace 0.31.1 allows remote attackers to cause a denial of service (invalid write and SEGV), related to the ReadImage function in input-bmp.c:353:25.
CVE-2017-7901 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2025-04-20 N/A
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
CVE-2017-7902 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2025-04-20 N/A
A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed.
CVE-2017-7905 1 Ge 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more 2025-04-20 N/A
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
CVE-2017-7907 1 Schneider-electric 1 Wonderware Historian Client 2025-04-20 N/A
An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.
CVE-2017-7909 1 Advantech B\+b Smartworx 2 Mesr901, Mesr901 Firmware 2025-04-20 N/A
A Use of Client-Side Authentication issue was discovered in Advantech B+B SmartWorx MESR901 firmware versions 1.5.2 and prior. The web interface uses JavaScript to check client authentication and redirect unauthorized users. Attackers may intercept requests and bypass authentication to access restricted web pages.
CVE-2017-7910 1 Digital Canal Structural 1 Wind Analysis 2025-04-20 N/A
A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be able to run arbitrary code by remotely exploiting an executable to perform a denial-of-service attack.
CVE-2017-7911 1 Cybervision 1 Kaa Iot Platform 2025-04-20 N/A
A Code Injection issue was discovered in CyberVision Kaa IoT Platform, Version 0.7.4. An insufficient-encapsulation vulnerability has been identified, which may allow remote code execution.
CVE-2017-7913 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2025-04-20 N/A
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.
CVE-2017-7914 1 Rockwellautomation 2 Panelview Plus 6 700-1500, Panelview Plus 6 700-1500 Firmware 2025-04-20 N/A
A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access.
CVE-2017-7915 1 Moxa 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more 2025-04-20 N/A
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
CVE-2017-7916 1 Abb 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more 2025-04-20 N/A
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.