| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-3263 | 1 Measuresoft | 1 Scadapro Server | 2025-04-16 | 7.8 High |
| The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges. | ||||
| CVE-2022-3397 | 1 Omron | 1 Cx-programmer | 2025-04-16 | 7.8 High |
| OMRON CX-Programmer 9.78 and prior is vulnerable to an Out-of-Bounds Write, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-3398 | 1 Omron | 1 Cx-programmer | 2025-04-16 | 7.8 High |
| OMRON CX-Programmer 9.78 and prior is vulnerable to an Out-of-Bounds Write, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-3396 | 1 Omron | 1 Cx-programmer | 2025-04-16 | 7.8 High |
| OMRON CX-Programmer 9.78 and prior is vulnerable to an Out-of-Bounds Write, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2021-27406 | 1 Perfact | 1 Openvpn-client | 2025-04-16 | 8.8 High |
| An attacker can take leverage on PerFact OpenVPN-Client versions 1.4.1.0 and prior to send the config command from any application running on the local host machine to force the back-end server into initializing a new open-VPN instance with arbitrary open-VPN configuration. This could result in the attacker achieving execution with privileges of a SYSTEM user. | ||||
| CVE-2022-1738 | 1 Fujielectric | 1 D300win | 2025-04-16 | 8.7 High |
| Fuji Electric D300win prior to version 3.7.1.17 is vulnerable to an out-of-bounds read, which could allow an attacker to leak sensitive data from the process memory. | ||||
| CVE-2022-2069 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2025-04-16 | 7.8 High |
| The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2022-40965 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API. | ||||
| CVE-2022-41555 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API. | ||||
| CVE-2022-40967 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-41701 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API. | ||||
| CVE-2022-41773 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-41133 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-41651 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API. | ||||
| CVE-2022-41702 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API. | ||||
| CVE-2022-3379 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by writing outside the memory buffer. | ||||
| CVE-2022-3378 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP 7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory write. | ||||
| CVE-2022-3377 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP 6 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory read. | ||||
| CVE-2022-41779 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution. | ||||
| CVE-2022-41644 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. | ||||