Export limit exceeded: 372303 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (372303 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-41688 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 9.8 Critical |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group. | ||||
| CVE-2022-41776 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 7.5 High |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords. | ||||
| CVE-2022-41629 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 7.5 High |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords. | ||||
| CVE-2022-3181 | 1 Trihedral | 1 Vtscada | 2025-04-16 | 7.5 High |
| An Improper Input Validation vulnerability exists in Trihedral VTScada version 12.0.38 and prior. A specifically malformed HTTP request could cause the affected VTScada to crash. Both local area network (LAN)-only and internet facing systems are affected. | ||||
| CVE-2022-3090 | 1 Redlion | 1 Crimson | 2025-04-16 | 7.5 High |
| Red Lion Controls Crimson 3.0 versions 707.000 and prior, Crimson 3.1 versions 3126.001 and prior, and Crimson 3.2 versions 3.2.0044.0 and prior are vulnerable to path traversal. When attempting to open a file using a specific path, the user's password hash is sent to an arbitrary host. This could allow an attacker to obtain user credential hashes. | ||||
| CVE-2022-2791 | 1 Emerson | 1 Proficy | 2025-04-16 | 5.9 Medium |
| Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC. | ||||
| CVE-2019-18265 | 1 Digitalalertsystems | 10 Dasdec I, Dasdec I Firmware, Dasdec Ii and 7 more | 2025-04-16 | 4.7 Medium |
| Digital Alert Systems’ DASDEC software prior to version 4.1 contains a cross-site scripting (XSS) vulnerability that allows remote attackers to inject arbitrary web script or HTML via the SSH username, username field of the login page, or via the HTTP host header. The injected content is stored in logs and rendered when viewed in the web application. | ||||
| CVE-2022-40204 | 1 Digitalalertsystems | 10 Dasdec I, Dasdec I Firmware, Dasdec Ii and 7 more | 2025-04-16 | 4.1 Medium |
| A cross-site scripting (XSS) vulnerability exists in all current versions of Digital Alert Systems DASDEC software via the Host Header in undisclosed pages after login. | ||||
| CVE-2022-2969 | 1 Deltaww | 1 Dialink | 2025-04-16 | 8.1 High |
| Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory. | ||||
| CVE-2022-2641 | 1 Hornerautomation | 2 Rcc972, Rcc972 Firmware | 2025-04-16 | 9.8 Critical |
| Horner Automation’s RCC 972 with firmware version 15.40 has a static encryption key on the device. This could allow an attacker to perform unauthorized changes to the device, remotely execute arbitrary code, or cause a denial-of-service condition. | ||||
| CVE-2022-2640 | 1 Hornerautomation | 2 Rcc972, Rcc972 Firmware | 2025-04-16 | 7.5 High |
| The Config-files of Horner Automation’s RCC 972 with firmware version 15.40 are encrypted with weak XOR encryption vulnerable to reverse engineering. This could allow an attacker to obtain credentials to run services such as File Transfer Protocol (FTP) and Hypertext Transfer Protocol (HTTP). | ||||
| CVE-2022-2642 | 1 Hornerautomation | 2 Rcc972, Rcc972 Firmware | 2025-04-16 | 7.5 High |
| Horner Automation’s RCC 972 firmware version 15.40 contains global variables. This could allow an attacker to read out sensitive values and variable keys from the device. | ||||
| CVE-2022-41653 | 1 Daikinlatam | 2 Svmpc1, Svmpc2 | 2025-04-16 | 9.8 Critical |
| Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system. | ||||
| CVE-2022-38355 | 1 Daikinlatam | 2 Svmpc1, Svmpc2 | 2025-04-16 | 7.5 High |
| Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to attackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication. | ||||
| CVE-2022-2757 | 1 Kingspan | 2 Tms300 Cs, Tms300 Cs Firmware | 2025-04-16 | 9.8 Critical |
| Due to the lack of adequately implemented access-control rules, all versions Kingspan TMS300 CS are vulnerable to an attacker viewing and modifying the application settings without authenticating by accessing a specific uniform resource locator (URL) on the webserver. | ||||
| CVE-2022-2660 | 1 Deltaww | 1 Dialink | 2025-04-16 | 9.8 Critical |
| Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine. | ||||
| CVE-2022-2966 | 1 Deltaww | 1 Dopsoft | 2025-04-16 | 3.3 Low |
| Out-of-bounds Read vulnerability in Delta Electronics DOPSoft.This issue affects DOPSoft: All Versions. | ||||
| CVE-2024-2152 | 1 Oretnom23 | 1 Online Mobile Store Management System | 2025-04-16 | 4.7 Medium |
| A vulnerability, which was classified as critical, has been found in SourceCodester Online Mobile Management Store 1.0. Affected by this issue is some unknown functionality of the file /admin/product/manage_product.php. The manipulation of the argument id leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255584. | ||||
| CVE-2024-25269 | 2 Libheif, Struktur | 2 Libheif, Libheif | 2025-04-16 | 7.5 High |
| libheif <= 1.17.6 contains a memory leak in the function JpegEncoder::Encode. This flaw allows an attacker to cause a denial of service attack. | ||||
| CVE-2024-20832 | 2 Samsung, Samsung Mobile | 2 Android, Samsung Mobile Devices | 2025-04-16 | 6.4 Medium |
| Heap overflow in Little Kernel in bootloader prior to SMR Mar-2024 Release 1 allows local privileged attackers to execute arbitrary code. | ||||