| CVE-2022-41701 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API. | ||||
| CVE-2022-41773 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-41133 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. | ||||
| CVE-2022-41651 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API. | ||||
| CVE-2022-41702 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.7 High |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API. | ||||
| CVE-2022-3379 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by writing outside the memory buffer. | ||||
| CVE-2022-3378 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP 7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory write. | ||||
| CVE-2022-3377 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| Horner Automation's Cscape version 9.90 SP 6 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory read. | ||||
| CVE-2022-41779 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution. | ||||
| CVE-2022-41644 | 1 Deltaww | 1 Infrasuite Device Master | 2025-04-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges. | ||||
| CVE-2022-40190 | 1 Sauter-controls | 1 Moduweb Firmware | 2025-04-16 | 8.8 High |
| SAUTER Controls moduWeb firmware version 2.7.1 is vulnerable to reflective cross-site scripting (XSS). The web application does not adequately sanitize request strings of malicious JavaScript. An attacker utilizing XSS could then execute malicious code in users’ browsers and steal sensitive information, including user credentials. | ||||
| CVE-2022-3703 | 1 Etictelecom | 14 Ras-c-100-lw, Ras-e-100, Ras-e-220 and 11 more | 2025-04-16 | 7.6 High |
| All versions of ETIC Telecom Remote Access Server (RAS) 4.5.0 and prior’s web portal is vulnerable to accepting malicious firmware packages that could provide a backdoor to an attacker and provide privilege escalation to the device. | ||||
| CVE-2022-43447 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-43452 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-41775 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-43506 | 1 Deltaww | 1 Diaenergie | 2025-04-16 | 8.8 High |
| SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network | ||||
| CVE-2022-3088 | 2 Debian, Moxa | 129 Debian Linux, Aig-301-ap-azu-lx, Aig-301-ap-azu-lx Firmware and 126 more | 2025-04-16 | 7.8 High |
| UC-8100A-ME-T System Image: Versions v1.0 to v1.6, UC-2100 System Image: Versions v1.0 to v1.12, UC-2100-W System Image: Versions v1.0 to v 1.12, UC-3100 System Image: Versions v1.0 to v1.6, UC-5100 System Image: Versions v1.0 to v1.4, UC-8100 System Image: Versions v3.0 to v3.5, UC-8100-ME-T System Image: Versions v3.0 and v3.1, UC-8200 System Image: v1.0 to v1.5, AIG-300 System Image: v1.0 to v1.4, UC-8410A with Debian 9 System Image: Versions v4.0.2 and v4.1.2, UC-8580 with Debian 9 System Image: Versions v2.0 and v2.1, UC-8540 with Debian 9 System Image: Versions v2.0 and v2.1, and DA-662C-16-LX (GLB) System Image: Versions v1.0.2 to v1.1.2 of Moxa's ARM-based computers have an execution with unnecessary privileges vulnerability, which could allow an attacker with user-level privileges to gain root privileges. | ||||
| CVE-2022-3086 | 1 Moxa | 100 Uc-2101-lx, Uc-2101-lx Firmware, Uc-2102-lx and 97 more | 2025-04-16 | 7.1 High |
| Cradlepoint IBR600 NCOS versions 6.5.0.160bc2e and prior are vulnerable to shell escape, which enables local attackers with non-superuser credentials to gain full, unrestrictive shell access which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-2002 | 1 Ge | 1 Cimplicity | 2025-04-16 | 7.8 High |
| GE CIMPICITY versions 2022 and prior is vulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. | ||||
| CVE-2022-2948 | 1 Ge | 1 Cimplicity | 2025-04-16 | 7.8 High |
| GE CIMPICITY versions 2022 and prior is vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code. | ||||