Export limit exceeded: 372217 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (372217 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-32941 1 Annke 2 N48pbb, N48pbb Firmware 2025-04-16 9.4 Critical
Annke N48PBB (Network Video Recorder) products of version 3.4.106 build 200422 and prior are vulnerable to a stack-based buffer overflow, which allows an unauthorized remote attacker to execute arbitrary code with the same privileges as the server user (root).
CVE-2022-1467 1 Aveva 2 Intouch Access Anywhere, Plant Scada Access Anywhere 2025-04-16 7.4 High
Windows OS can be configured to overlay a “language bar” on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS language bar to launch an OS command prompt, resulting in a context-escape from application into OS.
CVE-2021-32958 1 Claroty 1 Secure Remote Access 2025-04-16 5.5 Medium
Successful exploitation of this vulnerability on Claroty Secure Remote Access (SRA) Site versions 3.0 through 3.2 allows an attacker with local command line interface access to gain the secret key, subsequently allowing them to generate valid session tokens for the web user interface (UI). With access to the web UI an attacker can access assets managed by the SRA installation and could compromise the installation.
CVE-2022-1669 1 Circutor 2 Compact Dc-s Basic, Compact Dc-s Basic Firmware 2025-04-16 6.8 Medium
A buffer overflow vulnerability has been detected in the firewall function of the device management web portal. The device runs a CGI binary (index.cgi) to offer a management web application. Once authenticated with valid credentials in this web portal, a potential attacker could submit any "Address" value and it would be copied to a second variable with a "strcpy" vulnerable function without checking its length. Because of this, it is possible to send a long address value to overflow the process stack, controlling the function return address.
CVE-2021-32964 1 Aggsoft 1 Webserver 2025-04-16 6.5 Medium
The AGG Software Web Server version 4.0.40.1014 and prior is vulnerable to a path traversal attack, which may allow an attacker to read arbitrary files from the file system.
CVE-2021-32962 1 Aggsoft 1 Webserver 2025-04-16 8.2 High
The AGG Software Web Server version 4.0.40.1014 and prior is vulnerable to cross-site scripting, which may allow an attacker to remotely execute arbitrary code.
CVE-2021-32966 1 Philips 1 Interoperability Solution Xds 2025-04-16 3.7 Low
Philips Interoperability Solution XDS versions 2.5 through 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDAP system credentials.
CVE-2021-32989 1 Lcds 1 Laquis Scada 2025-04-16 9.3 Critical
When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting.
CVE-2021-32997 1 Bakerhughes 10 Bentley Nevada 3500\/22m \(288055-01\), Bentley Nevada 3500\/22m \(288055-01\) Firmware, Bentley Nevada 3500 Rack Configuration \(129133-01\) and 7 more 2025-04-16 8.2 High
The affected Baker Hughes Bentley Nevada products (3500 System 1 6.x, Part No. 3060/00 versions 6.98 and prior, 3500 System 1, Part No. 3071/xx & 3072/xx versions 21.1 HF1 and prior, 3500 Rack Configuration, Part No. 129133-01 versions 6.4 and prior, and 3500/22M Firmware, Part No. 288055-01 versions 5.05 and prior) utilize a weak encryption algorithm for storage and transmission of sensitive data, which may allow an attacker to more easily obtain credentials used for access.
CVE-2021-33016 1 Kuka 3 Kr C4, Kr C4 Firmware, Kss 2025-04-16 9.8 Critical
An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
CVE-2022-1261 1 Honeywell 1 Matrikon Opc Server 2025-04-16 5.8 Medium
Matrikon, a subsidary of Honeywell Matrikon OPC Server (all versions) is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges.
CVE-2022-1797 1 Rockwellautomation 18 Compact Guardlogix 5370, Compact Guardlogix 5370 Firmware, Compact Guardlogix 5380 and 15 more 2025-04-16 6.8 Medium
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.
CVE-2022-1660 1 Keysight 4 N6841a Rf, N6841a Rf Firmware, N6854a and 1 more 2025-04-16 9.8 Critical
The affected products are vulnerable of untrusted data due to deserialization without prior authorization/authentication, which may allow an attacker to remotely execute arbitrary code.
CVE-2022-1661 1 Keysight 4 N6841a Rf, N6841a Rf Firmware, N6854a and 1 more 2025-04-16 7.5 High
The affected products are vulnerable to directory traversal, which may allow an attacker to obtain arbitrary operating system files.
CVE-2020-36547 1 Ge 2 Voluson S8, Voluson S8 Firmware 2025-04-16 5.9 Medium
A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings.
CVE-2020-36548 1 Ge 2 Voluson S8, Voluson S8 Firmware 2025-04-16 5.9 Medium
A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host.
CVE-2022-1517 1 Illumina 8 Iseq 100, Local Run Manager, Miniseq and 5 more 2025-04-16 10 Critical
LRM utilizes elevated privileges. An unauthenticated malicious actor can upload and execute code remotely at the operating system level, which can allow an attacker to change settings, configurations, software, or access sensitive data on the affected produc. An attacker could also exploit this vulnerability to access APIs not intended for general use and interact through the network.
CVE-2022-1519 1 Illumina 8 Iseq 100, Local Run Manager, Miniseq and 5 more 2025-04-16 10 Critical
LRM does not restrict the types of files that can be uploaded to the affected product. A malicious actor can upload any file type, including executable code that allows for a remote code exploit.
CVE-2022-1518 1 Illumina 8 Iseq 100, Local Run Manager, Miniseq and 5 more 2025-04-16 10 Critical
LRM contains a directory traversal vulnerability that can allow a malicious actor to upload outside the intended directory structure.
CVE-2022-1521 1 Illumina 8 Iseq 100, Local Run Manager, Miniseq and 5 more 2025-04-16 9.1 Critical
LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data.