Export limit exceeded: 372282 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (372282 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-26131 1 Hegemonelectronics 2 Plc4trucks, Plc4trucks Firmware 2025-04-16 9.3 Critical
Power Line Communications PLC4TRUCKS J2497 trailer receivers are susceptible to remote RF induced signals.
CVE-2022-21146 1 Ipcomm 2 Ipdio, Ipdio Firmware 2025-04-16 6.3 Medium
Persistent cross-site scripting in the web interface of ipDIO allows an unauthenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into a specific parameter. The XSS payload will be executed when a legitimate user attempts to review history.
CVE-2022-24432 1 Ipcomm 2 Ipdio, Ipdio Firmware 2025-04-16 5.5 Medium
Persistent cross-site scripting (XSS) in the web interface of ipDIO allows an authenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into specific fields. The XSS payload will be executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration (Administrative Services).
CVE-2021-27416 1 Hitachienergy 1 Ellipse Enterprise Asset Management 2025-04-16 5.5 Medium
An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user’s session.
CVE-2021-27414 1 Hitachienergy 1 Ellipse Enterprise Asset Management 2025-04-16 5.5 Medium
An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials.
CVE-2022-25247 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 9.8 Critical
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution.
CVE-2022-25246 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 9.8 Critical
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
CVE-2022-25248 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 5.3 Medium
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) supplies the event log of the specific service.
CVE-2022-25249 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 7.5 High
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) (disregarding Axeda agent v6.9.2 and v6.9.3) is vulnerable to directory traversal, which could allow a remote unauthenticated attacker to obtain file system read access via web server..
CVE-2022-25250 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 7.5 High
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service.
CVE-2022-25252 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 7.5 High
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) when receiving certain input throws an exception. Services using said function do not handle the exception. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to crash the affected product.
CVE-2022-25251 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 9.8 Critical
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration.
CVE-2020-16232 1 Yokogawa 1 Widefield3 2025-04-16 2.8 Low
In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file.
CVE-2020-25180 3 Rockwellautomation, Schneider-electric, Xylem 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more 2025-04-16 5.3 Medium
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
CVE-2020-25197 1 Ge 6 Rt430, Rt430 Firmware, Rt431 and 3 more 2025-04-16 9.8 Critical
A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system.
CVE-2020-25193 1 Ge 6 Rt430, Rt430 Firmware, Rt431 and 3 more 2025-04-16 5.3 Medium
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection.
CVE-2021-27456 1 Phillips 22 Gemini 882160, Gemini 882160 Firmware, Gemini 882300 and 19 more 2025-04-16 2.4 Low
Philips Gemini PET/CT family software stores sensitive information in a removable media device that does not have built-in access control.
CVE-2021-27418 1 Ge 38 Multilin B30, Multilin B30 Firmware, Multilin B90 and 35 more 2025-04-16 5.3 Medium
GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings.
CVE-2021-27420 1 Ge 38 Multilin B30, Multilin B30 Firmware, Multilin B90 and 35 more 2025-04-16 5.3 Medium
GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels.
CVE-2021-27424 1 Ge 38 Multilin B30, Multilin B30 Firmware, Multilin B90 and 35 more 2025-04-16 5.3 Medium
GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to gain unauthorized information.