Export limit exceeded: 372313 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (372313 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-1403 | 1 Deltaww | 1 Asda Soft | 2025-04-16 | 7.8 High |
| ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds write condition. | ||||
| CVE-2022-1118 | 1 Rockwellautomation | 3 Connected Component Workbench, Isagraf Workbench, Safety Instrumented Systems Workstation | 2025-04-16 | 8.6 High |
| Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited | ||||
| CVE-2022-1358 | 1 Cambiumnetworks | 1 Cnmaestro | 2025-04-16 | 5.9 Medium |
| The affected On-Premise is vulnerable to data exfiltration through improper neutralization of special elements used in an SQL command. This could allow an attacker to exfiltrate and dump all data held in the cnMaestro database. | ||||
| CVE-2022-1361 | 1 Cambiumnetworks | 1 Cnmaestro | 2025-04-16 | 7.4 High |
| The affected On-Premise cnMaestro is vulnerable to a pre-auth data exfiltration through improper neutralization of special elements used in an SQL command. This could allow an attacker to exfiltrate data about other user’s accounts and devices. | ||||
| CVE-2020-16231 | 1 Bachmann | 40 Cpc210, Cpc210 Firmware, Cs200 and 37 more | 2025-04-16 | 7.2 High |
| The affected Bachmann Electronic M-Base Controllers of version MSYS v1.06.14 and later use weak cryptography to protect device passwords. Affected controllers that are actively supported include MX207, MX213, MX220, MC206, MC212, MC220, and MH230 hardware controllers, and affected end-of-life controller include MC205, MC210, MH212, ME203, CS200, MP213, MP226, MPC240, MPC265, MPC270, MPC293, MPE270, and CPC210 hardware controllers. Security Level 0 is set at default from the manufacturer, which could allow an unauthenticated remote attacker to gain access to the password hashes. Security Level 4 is susceptible if an authenticated remote attacker or an unauthenticated person with physical access to the device reads and decrypts the password to conduct further attacks. | ||||
| CVE-2020-14496 | 1 Mitsubishielectric | 29 Cpu Module Logging Configuration Tool, Cw Configurator, Data Transfer and 26 more | 2025-04-16 | 8.3 High |
| Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. | ||||
| CVE-2021-32935 | 1 Cognex | 1 In-sight Opc Server | 2025-04-16 | 8.8 High |
| The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation. | ||||
| CVE-2021-32965 | 1 Deltaww | 1 Diascreen | 2025-04-16 | 7.8 High |
| Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to type confusion, which may allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2021-32969 | 1 Deltaww | 1 Diascreen | 2025-04-16 | 7.8 High |
| Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to an out-of-bounds write condition, which may result in a system crash or allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2021-33014 | 1 Kuka | 3 Kr C4, Kr C4 Firmware, Kss | 2025-04-16 | 8.8 High |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. | ||||
| CVE-2022-27184 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| The affected product is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-28690 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| The affected product is vulnerable to an out-of-bounds write via uninitialized pointer, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-29488 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| The affected product is vulnerable to an out-of-bounds read via uninitialized pointer, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2022-30540 | 1 Hornerautomation | 1 Cscape | 2025-04-16 | 7.8 High |
| The affected product is vulnerable to a heap-based buffer overflow via uninitialized pointer, which may allow an attacker to execute arbitrary code | ||||
| CVE-2020-36549 | 1 Ge | 2 Voluson S8, Voluson S8 Firmware | 2025-04-16 | 8.8 High |
| A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed. | ||||
| CVE-2022-1524 | 1 Illumina | 8 Iseq 100, Local Run Manager, Miniseq and 5 more | 2025-04-16 | 7.4 High |
| LRM version 2.4 and lower does not implement TLS encryption. A malicious actor can MITM attack sensitive data in-transit, including credentials. | ||||
| CVE-2022-2104 | 1 Secheron | 2 Sepcos Control And Protection Relay, Sepcos Control And Protection Relay Firmware | 2025-04-16 | 9.9 Critical |
| The www-data (Apache web server) account is configured to run sudo with no password for many commands (including /bin/sh and /bin/bash). | ||||
| CVE-2022-2140 | 1 Smartics | 1 Smartics | 2025-04-16 | 8.8 High |
| Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters. | ||||
| CVE-2022-2253 | 1 Webhmi | 2 Webhmi, Webhmi Firmware | 2025-04-16 | 9.1 Critical |
| A user with administrative privileges in Distributed Data Systems WebHMI 4.1.1.7662 may send OS commands to execute on the host server. | ||||
| CVE-2022-2199 | 1 Micodus | 2 Mv720, Mv720 Firmware | 2025-04-16 | 7.5 High |
| The main MiCODUS MV720 GPS tracker web server has a reflected cross-site scripting vulnerability that could allow an attacker to gain control by tricking a user into making a request. | ||||