CVE-2016-5782 1 Locusenergy 6 Lgate 100, Lgate 101, Lgate 120 and 3 more 2025-04-20 N/A
An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information that is sent in the POST request.
CVE-2016-5786 1 Omnimetrix 1 Omniview 2025-04-20 N/A
An issue was discovered in OmniMetrix OmniView, Version 1.2. The OmniView web application transmits credentials with the HTTP protocol, which could be sniffed by an attacker that may result in the compromise of account credentials.
CVE-2016-5789 1 Jantek 2 Jtc-200, Jtc-200 Firmware 2025-04-20 N/A
A Cross-site Request Forgery issue was discovered in JanTek JTC-200, all versions. An attacker could perform actions with the same permissions as a victim user, provided the victim has an active session and is induced to trigger the malicious request.
CVE-2016-5791 1 Jantek 2 Jtc-200, Jtc-200 Firmware 2025-04-20 N/A
An Improper Authentication issue was discovered in JanTek JTC-200, all versions. The improper authentication could provide an undocumented BusyBox Linux shell accessible over the TELNET service without any authentication.
CVE-2016-5795 2 Automatedlogic, Carrier 3 I-vu, Sitescan Web, Automatedlogic Webctrl 2025-04-20 N/A
An XXE issue was discovered in Automated Logic Corporation (ALC) Liebert SiteScan Web Version 6.5 and prior, ALC WebCTRL Version 6.5 and prior, and Carrier i-Vu Version 6.5 and prior. An attacker could enter malicious input to WebCTRL, i-Vu, or SiteScan Web through a weakly configured XML parser causing the application to execute arbitrary code or disclose file contents from a server or connected network.
CVE-2016-5796 1 Fatek 2 Automation Fv Designer, Automation Pm Designer 2025-04-20 N/A
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. Sending additional valid packets could allow the attacker to cause a crash or to execute arbitrary code, because of Improper Restriction of Operations within the Bounds of a Memory Buffer.
CVE-2016-5798 1 Fatek 2 Automation Fv Designer, Automation Pm Designer 2025-04-20 N/A
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. By sending additional valid packets, an attacker could trigger a stack-based buffer overflow and cause a crash. Also, a malicious attacker can trigger a remote buffer overflow on the Fatek Communication Server.
CVE-2016-5801 1 Omnimetrix 1 Omniview 2025-04-20 N/A
An issue was discovered in OmniMetrix OmniView, Version 1.2. Insufficient password requirements for the OmniView web application may allow an attacker to gain access by brute forcing account passwords.
CVE-2016-5802 1 Delta Electronics 3 Ispsoft, Pmsoft, Wplsoft 2025-04-20 N/A
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to 2.10.10. Multiple instances of out-of-bounds write conditions may allow malicious files to be read and executed by the affected software.
CVE-2016-5803 1 Ca Technologies 1 Unified Infrastructure Management 2025-04-20 N/A
An issue was discovered in CA Unified Infrastructure Management Version 8.47 and earlier. The Unified Infrastructure Management software uses external input to construct a pathname that should be within a restricted directory, but it does not properly neutralize sequences such as ".." that can resolve to a location that is outside of that directory.
CVE-2016-5805 1 Delta Electronics 3 Ispsoft, Pmsoft, Wplsoft 2025-04-20 N/A
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to2.10.10. There are multiple instances of heap-based buffer overflows that may allow malicious files to cause the execution of arbitrary code or a denial of service.
CVE-2016-5809 1 Schneider-electric 6 Ion5000, Ion7300, Ion7500 and 3 more 2025-04-20 N/A
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
CVE-2016-5810 1 Advantech 1 Webaccess 2025-04-20 N/A
upAdminPg.asp in Advantech WebAccess before 8.1_20160519 allows remote authenticated administrators to obtain sensitive password information via unspecified vectors.
CVE-2016-5811 1 Visonic 2 Powerlink2, Powerlink2 Firmware 2025-04-20 6.1 Medium
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. User controlled input is not neutralized prior to being placed in web page output (CROSS-SITE SCRIPTING).
CVE-2016-5813 1 Visonic 2 Powerlink2, Powerlink2 Firmware 2025-04-20 N/A
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. When a specific URL to an image is accessed, the downloaded image carries with it source code used in the web server (INFORMATION EXPOSURE).
CVE-2016-5815 1 Schneider-electric 6 Ion5000, Ion7300, Ion7500 and 3 more 2025-04-20 N/A
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
CVE-2016-5816 1 Westermo 8 Mrd-305-din, Mrd-305-din Firmware, Mrd-315-din and 5 more 2025-04-20 N/A
A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source.
CVE-2016-5818 1 Schneider-electric 2 Powerlogic Pm8ecc, Powerlogic Pm8ecc Firmware 2025-04-20 N/A
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.
CVE-2016-5822 1 Huawei 1 Oceanstor 5800 V3 2025-04-20 N/A
Huawei Oceanstor 5800 before V300R002C10SPC100 allows remote attackers to cause a denial of service (CPU consumption) via a large number of crafted HTTP packets.
CVE-2016-5823 1 Libical Project 1 Libical 2025-04-20 N/A
The icalproperty_new_clone function in libical 0.47 and 1.0 allows remote attackers to cause a denial of service (use-after-free) via a crafted ics file.