Export limit exceeded: 376601 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (376601 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-5122 3 Debian, Google, Redhat 3 Debian Linux, Chrome, Rhel Extras 2025-04-20 N/A
Inappropriate use of table size handling in V8 in Google Chrome prior to 61.0.3163.100 for Windows allowed a remote attacker to trigger out-of-bounds access via a crafted HTML page.
CVE-2017-5137 1 Sendquick 4 Avera Sms Gateway, Avera Sms Gateway Firmware, Entera Sms Gateway and 1 more 2025-04-20 N/A
An issue was discovered on SendQuick Entera and Avera devices before 2HF16. An attacker could request and download the SMS logs from an unauthenticated perspective.
CVE-2017-5139 1 Honeywell 1 Xl Web Ii Controller 2025-04-20 N/A
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password.
CVE-2017-5141 1 Honeywell 1 Xl Web Ii Controller 2025-04-20 N/A
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. An attacker can establish a new user session, without invalidating any existing session identifier, which gives the opportunity to steal authenticated sessions (SESSION FIXATION).
CVE-2017-5142 1 Honeywell 1 Xl Web Ii Controller 2025-04-20 N/A
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user with low privileges is able to open and change the parameters by accessing a specific URL because of Improper Privilege Management.
CVE-2017-5144 1 Carlosgavazzi 4 Vmu-c Em, Vmu-c Em Firmware, Vmu-c Pv and 1 more 2025-04-20 N/A
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.
CVE-2017-5145 1 Carlosgavazzi 4 Vmu-c Em, Vmu-c Em Firmware, Vmu-c Pv and 1 more 2025-04-20 N/A
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
CVE-2017-5146 1 Carlosgavazzi 4 Vmu-c Em, Vmu-c Em Firmware, Vmu-c Pv and 1 more 2025-04-20 N/A
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text.
CVE-2017-5147 1 Azeotech 1 Daqfactory 2025-04-20 N/A
An Uncontrolled Search Path Element issue was discovered in AzeoTech DAQFactory versions prior to 17.1. An uncontrolled search path element vulnerability has been identified, which may execute malicious DLL files that have been placed within the search path.
CVE-2017-5149 1 Abbott 3 Merlin\@home Ex1100, Merlin\@home Ex1150, Merlin\@home Firmware 2025-04-20 8.9 High
An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 (RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability). The identities of the endpoints for the communication channel between the transmitter and St. Jude Medical's web site, Merlin.net, are not verified. This may allow a man-in-the-middle attacker to access or influence communications between the identified endpoints.
CVE-2017-5151 1 Panasonic 1 Video Insight Web Client 2025-04-20 7.3 High
An issue was discovered in VideoInsight Web Client Version 6.3.5.11 and previous versions. A SQL Injection vulnerability has been identified, which may allow remote code execution.
CVE-2017-5154 1 Advantech 1 Webaccess 2025-04-20 N/A
An issue was discovered in Advantech WebAccess Version 8.1. To be able to exploit the SQL injection vulnerability, an attacker must supply malformed input to the WebAccess software. Successful attack could result in administrative access to the application and its data files.
CVE-2017-5155 1 Schneider-electric 1 Wonderware Historian 2025-04-20 N/A
An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.
CVE-2017-5156 1 Aveva 1 Wonderware Intouch Access Anywhere 2025-04-20 8.8 High
A Cross-Site Request Forgery issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The client request may be forged from a different site. This will allow an external site to access internal RDP systems on behalf of the currently logged in user.
CVE-2017-5157 2 Schneider-electric, Schneider Electric 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware 2025-04-20 N/A
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.
CVE-2017-5158 1 Aveva 1 Wonderware Intouch Access Anywhere 2025-04-20 9.8 Critical
An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified.
CVE-2017-5159 1 Phoenixcontact 1 Mguard Firmware 2025-04-20 9.8 Critical
An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0. When updating an mGuard device to Version 8.4.0 via the update-upload facility, the update will succeed, but it will reset the password of the admin user to its default value.
CVE-2017-5161 1 Sielcosistemi 2 Winlog Lite, Winlog Pro 2025-04-20 N/A
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL.
CVE-2017-5162 1 Binom3 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware 2025-04-20 N/A
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
CVE-2017-5163 1 Belden Hirschmann 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware 2025-04-20 N/A
An issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. After an administrator downloads a configuration file, a copy of the configuration file, which includes hashes of user passwords, is saved to a location that is accessible without authentication by path traversal.