Export limit exceeded: 376134 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (376134 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-5157 | 2 Schneider-electric, Schneider Electric | 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code. | ||||
| CVE-2017-5158 | 1 Aveva | 1 Wonderware Intouch Access Anywhere | 2025-04-20 | 9.8 Critical |
| An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified. | ||||
| CVE-2017-5159 | 1 Phoenixcontact | 1 Mguard Firmware | 2025-04-20 | 9.8 Critical |
| An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0. When updating an mGuard device to Version 8.4.0 via the update-upload facility, the update will succeed, but it will reset the password of the admin user to its default value. | ||||
| CVE-2017-5161 | 1 Sielcosistemi | 2 Winlog Lite, Winlog Pro | 2025-04-20 | N/A |
| An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL. | ||||
| CVE-2017-5162 | 1 Binom3 | 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware | 2025-04-20 | N/A |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. | ||||
| CVE-2017-5163 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2025-04-20 | N/A |
| An issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. After an administrator downloads a configuration file, a copy of the configuration file, which includes hashes of user passwords, is saved to a location that is accessible without authentication by path traversal. | ||||
| CVE-2017-5164 | 1 Binom3 | 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware | 2025-04-20 | N/A |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROSS-SITE SCRIPTING). | ||||
| CVE-2017-5166 | 1 Binom3 | 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware | 2025-04-20 | N/A |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device. | ||||
| CVE-2017-5169 | 1 Hanwha-security | 1 Smart Security Manager | 2025-04-20 | 7.5 High |
| An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Cross Site Request Forgery vulnerabilities have been identified. The flaws exist within the Redis and Apache Felix Gogo servers that are installed as part of this product. By issuing specific HTTP Post requests, an attacker can gain system level access to a remote shell session. Smart Security Manager Versions 1.5 and prior are affected by these vulnerabilities. These vulnerabilities can allow for remote code execution. | ||||
| CVE-2017-5173 | 1 Geutebrueck | 2 Ip Camera G-cam Efd-2250, Ip Camera G-cam Efd-2250 Firmware | 2025-04-20 | 9.8 Critical |
| An Improper Neutralization of Special Elements (in an OS command) issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An improper neutralization of special elements vulnerability has been identified. If special elements are not properly neutralized, an attacker can call multiple parameters that can allow access to the root level operating system which could allow remote code execution. | ||||
| CVE-2017-5174 | 1 Geutebruck | 2 Ip Camera G-cam Efd-2250, Ip Camera G-cam Efd-2250 Firmware | 2025-04-20 | N/A |
| An Authentication Bypass issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An authentication bypass vulnerability has been identified. The existing file system architecture could allow attackers to bypass the access control that may allow remote code execution. | ||||
| CVE-2017-5177 | 1 Vipa Controls | 2 Winplc7, Winplc7 Firmware | 2025-04-20 | N/A |
| A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution. | ||||
| CVE-2017-5178 | 1 Schneider-electric | 3 Tableau Desktop, Tableau Server, Wonderware Intelligence | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access. | ||||
| CVE-2017-5180 | 1 Firejail Project | 1 Firejail | 2025-04-20 | N/A |
| Firejail before 0.9.44.4 and 0.9.38.x LTS before 0.9.38.8 LTS does not consider the .Xauthority case during its attempt to prevent accessing user files with an euid of zero, which allows local users to conduct sandbox-escape attacks via vectors involving a symlink and the --private option. | ||||
| CVE-2017-5183 | 1 Netiq | 1 Access Manager | 2025-04-20 | N/A |
| NetIQ Access Manager 4.2.2 and 4.3.x before 4.3.1+, when configured as an Identity Server, has XSS in the AssertionConsumerServiceURL field of a signed AuthnRequest in a samlp:AuthnRequest document. | ||||
| CVE-2017-5184 | 1 Microfocus | 1 Sentinel | 2025-04-20 | N/A |
| A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow leakage of information (account enumeration). | ||||
| CVE-2017-5185 | 1 Microfocus | 1 Sentinel | 2025-04-20 | N/A |
| A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow remote denial of service. | ||||
| CVE-2017-5187 | 1 Microfocus | 4 Directory Server, Enterprise Developer, Enterprise Server and 1 more | 2025-04-20 | N/A |
| A Cross-Site Request Forgery (CWE-352) vulnerability in Directory Server (aka Enterprise Server Administration web UI) in Micro Focus Enterprise Developer and Enterprise Server 2.3 and earlier, 2.3 Update 1 before Hotfix 8, and 2.3 Update 2 before Hotfix 9 allows remote unauthenticated attackers to view and alter (CWE-275) configuration information and inject OS commands (CWE-78) via forged requests. | ||||
| CVE-2017-5190 | 1 Netiq | 1 Access Manager | 2025-04-20 | N/A |
| NetIQ Access Manager 4.2 before SP3 HF1 and 4.3 before SP1 HF1, when configured as a SAML 2.0 Identity Server with Virtual Attributes, has a concurrency issue causing information leakage, related to a stale profile. | ||||
| CVE-2017-5191 | 1 Netiq | 1 Access Manager | 2025-04-20 | N/A |
| An XSS vulnerability on the /NAGErrors URI in NetIQ Access Manager 4.2 and 4.3 exists because Access Gateway Error pages do not validate the HTTP Referer header. | ||||