CVE-2017-5158 1 Aveva 1 Wonderware Intouch Access Anywhere 2025-04-20 9.8 Critical
An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified.
CVE-2017-5159 1 Phoenixcontact 1 Mguard Firmware 2025-04-20 9.8 Critical
An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0. When updating an mGuard device to Version 8.4.0 via the update-upload facility, the update will succeed, but it will reset the password of the admin user to its default value.
CVE-2017-5160 1 Aveva 1 Wonderware Intouch Access Anywhere 2025-04-20 5.3 Medium
An Inadequate Encryption Strength issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The software will connect via Transport Layer Security without verifying the peer's SSL certificate properly.
CVE-2017-5161 1 Sielcosistemi 2 Winlog Lite, Winlog Pro 2025-04-20 N/A
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL.
CVE-2017-5162 1 Binom3 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware 2025-04-20 N/A
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
CVE-2017-5163 1 Belden Hirschmann 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware 2025-04-20 N/A
An issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. After an administrator downloads a configuration file, a copy of the configuration file, which includes hashes of user passwords, is saved to a location that is accessible without authentication by path traversal.
CVE-2017-5164 1 Binom3 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware 2025-04-20 N/A
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROSS-SITE SCRIPTING).
CVE-2017-5165 1 Binom3 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware 2025-04-20 N/A
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
CVE-2017-5166 1 Binom3 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware 2025-04-20 N/A
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
CVE-2017-5167 1 Binom3 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware 2025-04-20 N/A
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
CVE-2017-5168 1 Hanwha-security 1 Smart Security Manager 2025-04-20 7.5 High
An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Path Traversal vulnerabilities have been identified. The flaws exist within the ActiveMQ Broker service that is installed as part of the product. By issuing specific HTTP requests, if a user visits a malicious page, an attacker can gain access to arbitrary files on the server. Smart Security Manager Versions 1.4 and prior to 1.31 are affected by these vulnerabilities. These vulnerabilities can allow for remote code execution.
CVE-2017-5169 1 Hanwha-security 1 Smart Security Manager 2025-04-20 7.5 High
An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Cross Site Request Forgery vulnerabilities have been identified. The flaws exist within the Redis and Apache Felix Gogo servers that are installed as part of this product. By issuing specific HTTP Post requests, an attacker can gain system level access to a remote shell session. Smart Security Manager Versions 1.5 and prior are affected by these vulnerabilities. These vulnerabilities can allow for remote code execution.
CVE-2017-5173 1 Geutebrueck 2 Ip Camera G-cam Efd-2250, Ip Camera G-cam Efd-2250 Firmware 2025-04-20 9.8 Critical
An Improper Neutralization of Special Elements (in an OS command) issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An improper neutralization of special elements vulnerability has been identified. If special elements are not properly neutralized, an attacker can call multiple parameters that can allow access to the root level operating system which could allow remote code execution.
CVE-2017-5174 1 Geutebruck 2 Ip Camera G-cam Efd-2250, Ip Camera G-cam Efd-2250 Firmware 2025-04-20 N/A
An Authentication Bypass issue was discovered in Geutebruck IP Camera G-Cam/EFD-2250 Version 1.11.0.12. An authentication bypass vulnerability has been identified. The existing file system architecture could allow attackers to bypass the access control that may allow remote code execution.
CVE-2017-5176 1 Rockwellautomation 8 9328-ccwdevdee, 9328-ccwdevene, 9328-ccwdevese and 5 more 2025-04-20 N/A
A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges.
CVE-2017-5177 1 Vipa Controls 2 Winplc7, Winplc7 Firmware 2025-04-20 N/A
A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution.
CVE-2017-5178 1 Schneider-electric 3 Tableau Desktop, Tableau Server, Wonderware Intelligence 2025-04-20 N/A
An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access.
CVE-2017-5180 1 Firejail Project 1 Firejail 2025-04-20 N/A
Firejail before 0.9.44.4 and 0.9.38.x LTS before 0.9.38.8 LTS does not consider the .Xauthority case during its attempt to prevent accessing user files with an euid of zero, which allows local users to conduct sandbox-escape attacks via vectors involving a symlink and the --private option.
CVE-2017-5183 1 Netiq 1 Access Manager 2025-04-20 N/A
NetIQ Access Manager 4.2.2 and 4.3.x before 4.3.1+, when configured as an Identity Server, has XSS in the AssertionConsumerServiceURL field of a signed AuthnRequest in a samlp:AuthnRequest document.
CVE-2017-5184 1 Microfocus 1 Sentinel 2025-04-20 N/A
A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow leakage of information (account enumeration).