Export limit exceeded: 364491 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (364491 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-6007 | 1 Sophos | 1 Hitmanpro | 2025-04-20 | N/A |
| A kernel pool overflow in the driver hitmanpro37.sys in Sophos SurfRight HitmanPro before 3.7.20 Build 286 (included in the HitmanPro.Alert solution and Sophos Clean) allows local users to crash the OS via a malformed IOCTL call. | ||||
| CVE-2017-6008 | 1 Sophos | 1 Hitmanpro | 2025-04-20 | N/A |
| A kernel pool overflow in the driver hitmanpro37.sys in Sophos SurfRight HitmanPro before 3.7.20 Build 286 (included in the HitmanPro.Alert solution and Sophos Clean) allows local users to escalate privileges via a malformed IOCTL call. | ||||
| CVE-2017-6009 | 3 Debian, Icoutils Project, Redhat | 9 Debian Linux, Icoutils, Enterprise Linux and 6 more | 2025-04-20 | N/A |
| An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "decode_ne_resource_id" function in the "restable.c" source file. This is happening because the "len" parameter for memcpy is not checked for size and thus becomes a negative integer in the process, resulting in a failed memcpy. This affects wrestool. | ||||
| CVE-2017-6010 | 3 Debian, Icoutils Project, Redhat | 9 Debian Linux, Icoutils, Enterprise Linux and 6 more | 2025-04-20 | N/A |
| An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "extract_icons" function in the "extract.c" source file. This issue can be triggered by processing a corrupted ico file and will result in an icotool crash. | ||||
| CVE-2017-6011 | 3 Debian, Icoutils Project, Redhat | 9 Debian Linux, Icoutils, Enterprise Linux and 6 more | 2025-04-20 | N/A |
| An issue was discovered in icoutils 0.31.1. An out-of-bounds read leading to a buffer overflow was observed in the "simple_vec" function in the "extract.c" source file. This affects icotool. | ||||
| CVE-2017-6013 | 1 Intelliants | 1 Subrion Cms | 2025-04-20 | N/A |
| Subrion CMS 4.0.5.10 has SQL injection in admin/database/ via the query parameter. | ||||
| CVE-2017-6178 | 1 Usbpcap Project | 1 Usbpcap | 2025-04-20 | N/A |
| The IofCallDriver function in USBPcap 1.1.0.0 allows local users to gain privileges via a crafted 0x00090028 IOCTL call, which triggers a NULL pointer dereference. | ||||
| CVE-2017-6014 | 2 Debian, Wireshark | 2 Debian Linux, Wireshark | 2025-04-20 | N/A |
| In Wireshark 2.2.4 and earlier, a crafted or malformed STANAG 4607 capture file will cause an infinite loop and memory exhaustion. If the packet size field in a packet header is null, the offset to read from will not advance, causing continuous attempts to read the same zero length packet. This will quickly exhaust all system memory. | ||||
| CVE-2017-6016 | 1 Leao Consultoria E Desenvolvimento De Sistemas | 1 Ltda Me Laquis Scada | 2025-04-20 | N/A |
| An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges. | ||||
| CVE-2017-6018 | 1 Bbraun | 2 Spacestation, Station Firmware | 2025-04-20 | N/A |
| An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input. | ||||
| CVE-2017-6019 | 1 Schneider-electric | 2 Conext Combox 865-1058, Conext Combox 865-1058 Firmware | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot. | ||||
| CVE-2017-6022 | 1 Bd | 2 Kla Journal Service, Performa | 2025-04-20 | N/A |
| A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. | ||||
| CVE-2017-6023 | 1 Fatek | 5 Ethernet Module Configuration Tool Cbe Firmware, Ethernet Module Configuration Tool Cbeh Firmware, Ethernet Module Configuration Tool Cm25e Firmware and 2 more | 2025-04-20 | 9.8 Critical |
| An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device. | ||||
| CVE-2017-6024 | 1 Rockwellautomation | 4 Compactlogix 5380, Compactlogix 5380 Firmware, Controllogix 5580 and 1 more | 2025-04-20 | 5.9 Medium |
| A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller. | ||||
| CVE-2017-6025 | 1 Codesys | 1 Web Server | 2025-04-20 | N/A |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. | ||||
| CVE-2017-6026 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2025-04-20 | 9.1 Critical |
| A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised. | ||||
| CVE-2017-6027 | 1 Codesys | 1 Web Server | 2025-04-20 | N/A |
| An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution. | ||||
| CVE-2017-6028 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2025-04-20 | 9.8 Critical |
| An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application. | ||||
| CVE-2017-6029 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2025-04-20 | N/A |
| A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution. | ||||
| CVE-2017-6031 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2025-04-20 | N/A |
| A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution. | ||||