Export limit exceeded: 374264 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 374264 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (374264 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-37540 | 1 Hcltech | 1 Sametime | 2026-01-09 | 3.9 Low |
| Sametime Connect desktop chat client includes, but does not use or require, the use of an Eclipse feature called Secure Storage. Using this Eclipse feature to store sensitive data can lead to exposure of that data. | ||||
| CVE-2025-52515 | 1 Samsung | 16 Exynos, Exynos 1330, Exynos 1330 Firmware and 13 more | 2026-01-09 | 5.1 Medium |
| An issue was discovered in the Camera in Samsung Mobile Processor and Wearable Processor Exynos 1330, 1380, 1480, 2400, 1580, 2500. A race condition in the issimian device driver results in an out-of-bounds access, leading to a denial of service. | ||||
| CVE-2025-52516 | 1 Samsung | 16 Exynos, Exynos 1330, Exynos 1330 Firmware and 13 more | 2026-01-09 | 6.2 Medium |
| An issue was discovered in the Camera in Samsung Mobile Processor and Wearable Processor Exynos 1330, 1380, 1480, 2400, 1580, 2500. An invalid kernel address dereference in the issimian device driver leads to a denial of service. | ||||
| CVE-2024-47253 | 1 2n | 1 Access Commander | 2026-01-09 | 7.2 High |
| In 2N Access Commander versions 3.1.1.2 and prior, a Path Traversal vulnerability could allow an attacker with administrative privileges to write files on the filesystem and potentially achieve arbitrary remote code execution. This vulnerability cannot be exploited by users with lower privilege roles. | ||||
| CVE-2024-47255 | 1 2n | 1 Access Commander | 2026-01-09 | 4.7 Medium |
| In 2N Access Commander versions 3.1.1.2 and prior, a local attacker can escalate their privileges in the system which could allow for arbitrary code execution with root permissions. | ||||
| CVE-2024-47254 | 1 2n | 1 Access Commander | 2026-01-09 | 6.3 Medium |
| In 2N Access Commander versions 3.1.1.2 and prior, an Insufficient Verification of Data Authenticity vulnerability could allow an attacker to escalate their privileges and gain root access to the system. | ||||
| CVE-2025-40361 | 2026-01-09 | 5.5 Medium | ||
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. | ||||
| CVE-2024-7587 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | 7.8 High |
| Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32. | ||||
| CVE-2022-33320 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | 7.8 High |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes. | ||||
| CVE-2022-33319 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | 8.2 High |
| Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server. | ||||
| CVE-2022-33318 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | 9.8 Critical |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server. | ||||
| CVE-2022-33317 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | 7.8 High |
| Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes. | ||||
| CVE-2022-33316 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | 7.8 High |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | ||||
| CVE-2022-33315 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | 7.8 High |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | ||||
| CVE-2022-29834 | 1 Iconics | 1 Genesis64 | 2026-01-09 | 7.5 High |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server or ICONICS suite server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 or ICONICS Suite mobile monitoring application and accessing the monitoring screen. | ||||
| CVE-2026-22636 | 2026-01-09 | N/A | ||
| Not used | ||||
| CVE-2026-22635 | 2026-01-09 | N/A | ||
| Not used | ||||
| CVE-2026-22634 | 2026-01-09 | N/A | ||
| Not used | ||||
| CVE-2026-22633 | 2026-01-09 | N/A | ||
| Not used | ||||
| CVE-2026-22632 | 2026-01-09 | N/A | ||
| Not used | ||||