Export limit exceeded: 371330 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (371330 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-27437 | 1 Advantech | 1 Wise-paas\/rmm | 2024-11-21 | 9.1 Critical |
| The affected product allows attackers to obtain sensitive information from the WISE-PaaS dashboard. The system contains a hard-coded administrator username and password that can be used to query Grafana APIs. Authentication is not required for exploitation on the WISE-PaaS/RMM (versions prior to 9.0.1). | ||||
| CVE-2021-27436 | 1 Advantech | 1 Webaccess\/scada | 2024-11-21 | 6.1 Medium |
| WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions. | ||||
| CVE-2021-27434 | 2 Microsoft, Unified-automation | 2 .net Framework, .net Based Opc Ua Client\/server Sdk | 2024-11-21 | 7.5 High |
| Products with Unified Automation .NET based OPC UA Client/Server SDK Bundle: Versions V3.0.7 and prior (.NET 4.5, 4.0, and 3.5 Framework versions only) are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow. | ||||
| CVE-2021-27432 | 1 Opcfoundation | 2 Ua-.net-legacy, Ua .net Standard Stack | 2024-11-21 | 7.5 High |
| OPC Foundation UA .NET Standard versions prior to 1.4.365.48 and OPC UA .NET Legacy are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow. | ||||
| CVE-2021-27429 | 1 Ti | 14 Cc3200, Cc3220r, Cc3220s and 11 more | 2024-11-21 | 7.4 High |
| Texas Instruments TI-RTOS returns a valid pointer to a small buffer on extremely large values. This can trigger an integer overflow vulnerability in 'HeapTrack_alloc' and result in code execution. | ||||
| CVE-2021-27413 | 1 Omron | 2 Cx-one, Cx-server | 2024-11-21 | 7.8 High |
| Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2021-27412 | 1 Deltaww | 1 Dopsoft | 2024-11-21 | 7.8 High |
| Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2021-27410 | 1 Hillrom | 9 Connex Central Station, Connex Device Integration Suite Network Connectivity Engine, Connex Integrated Wall System and 6 more | 2024-11-21 | 9.8 Critical |
| The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00). | ||||
| CVE-2021-27408 | 1 Hillrom | 9 Connex Central Station, Connex Device Integration Suite Network Connectivity Engine, Connex Integrated Wall System and 6 more | 2024-11-21 | 7.5 High |
| The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00). | ||||
| CVE-2021-27405 | 1 Scrapbox-parser Project | 1 Scrapbox-parser | 2024-11-21 | 7.5 High |
| A ReDoS (regular expression denial of service) flaw was found in the @progfay/scrapbox-parser package before 6.0.3 for Node.js. | ||||
| CVE-2021-27404 | 1 Asus | 2 Askey Rtf8115vw, Askey Rtf8115vw Firmware | 2024-11-21 | 6.1 Medium |
| Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow injection of a Host HTTP header. | ||||
| CVE-2021-27403 | 1 Asus | 2 Askey Rtf8115vw, Askey Rtf8115vw Firmware | 2024-11-21 | 6.1 Medium |
| Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow cgi-bin/te_acceso_router.cgi curWebPage XSS. | ||||
| CVE-2021-27402 | 1 Mitel | 1 Micollab | 2024-11-21 | 6.5 Medium |
| The SAS Admin portal of Mitel MiCollab before 9.2 FP2 could allow an unauthenticated attacker to access (view and modify) user data by injecting arbitrary directory paths due to improper URL validation, aka Directory Traversal. | ||||
| CVE-2021-27401 | 1 Mitel | 1 Micollab | 2024-11-21 | 6.1 Medium |
| The Join Meeting page of Mitel MiCollab Web Client before 9.2 FP2 could allow an attacker to access (view and modify) user data by executing arbitrary code due to insufficient input validation, aka Cross-Site Scripting (XSS). | ||||
| CVE-2021-27400 | 1 Hashicorp | 1 Vault | 2024-11-21 | 7.5 High |
| HashiCorp Vault and Vault Enterprise Cassandra integrations (storage backend and database secrets engine plugin) did not validate TLS certificates when connecting to Cassandra clusters. Fixed in 1.6.4 and 1.7.1 | ||||
| CVE-2021-27399 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820) | ||||
| CVE-2021-27398 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290) | ||||
| CVE-2021-27397 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287) | ||||
| CVE-2021-27396 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2024-11-21 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279) | ||||
| CVE-2021-27395 | 1 Siemens | 4 Simatic Process Historian 2013, Simatic Process Historian 2014, Simatic Process Historian 2019 and 1 more | 2024-11-21 | 8.1 High |
| A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data. | ||||