Export limit exceeded: 366528 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (366528 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-22705 | 1 Schneider-electric | 9 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 6 more | 2024-11-21 | 7.8 High |
| Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert | ||||
| CVE-2021-22704 | 1 Schneider-electric | 10 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 7 more | 2024-11-21 | 9.1 Critical |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. | ||||
| CVE-2021-22703 | 1 Schneider-electric | 20 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion7650 and 17 more | 2024-11-21 | 7.5 High |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device. | ||||
| CVE-2021-22701 | 1 Schneider-electric | 21 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion7410 and 18 more | 2024-11-21 | 4.5 Medium |
| A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface. | ||||
| CVE-2021-22699 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2024-11-21 | 7.5 High |
| Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP. | ||||
| CVE-2021-22698 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2024-11-21 | 7.8 High |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | ||||
| CVE-2021-22697 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2024-11-21 | 7.8 High |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | ||||
| CVE-2021-22684 | 1 Samsung | 1 Tizenrt | 2024-11-21 | 7.5 High |
| Tizen RT RTOS version 3.0.GBB is vulnerable to integer wrap-around in functions_calloc and mm_zalloc. This improper memory assignment can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash | ||||
| CVE-2021-22683 | 1 Fatek | 1 Fvdesigner | 2024-11-21 | 7.8 High |
| Fatek FvDesigner Version 1.5.76 and prior is vulnerable to an out-of-bounds write while processing project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. | ||||
| CVE-2021-22682 | 1 Hornerautomation | 1 Cscape | 2024-11-21 | 7.8 High |
| Cscape (All versions prior to 9.90 SP4) is configured by default to be installed for all users, which allows full permissions, including read/write access. This may allow unprivileged users to modify the binaries and configuration files and lead to local privilege escalation. | ||||
| CVE-2021-22679 | 1 Ti | 7 Cc3100 Software Development Kit, Cc3200 Software Development Kit, Simplelink Cc13x0 Software Development Kit and 4 more | 2024-11-21 | 9.8 Critical |
| The affected product is vulnerable to an integer overflow while processing HTTP headers, which may allow an attacker to remotely execute code on the SimpleLink Wi-Fi (MSP432E4 SDK: v4.20.00.12 and prior, CC32XX SDK v4.30.00.06 and prior, CC13X0 SDK versions prior to v4.10.03, CC13X2 and CC26XX SDK versions prior to v4.40.00, CC3200 SDK v1.5.0 and prior, CC3100 SDK v1.3.0 and prior). | ||||
| CVE-2021-22678 | 1 Hornerautomation | 1 Cscape | 2024-11-21 | 7.8 High |
| Cscape (All versions prior to 9.90 SP4) lacks proper validation of user-supplied data when parsing project files. This could lead to memory corruption. An attacker could leverage this vulnerability to execute code in the context of the current process. | ||||
| CVE-2021-22677 | 1 Ti | 7 Cc3100 Software Development Kit, Cc3200 Software Development Kit, Simplelink Cc13x0 Software Development Kit and 4 more | 2024-11-21 | 7.8 High |
| An integer overflow exists in the APIs of the host MCU while trying to connect to a WIFI network may lead to issues such as a denial-of-service condition or code execution on the SimpleLink Wi-Fi (MSP432E4 SDK: v4.20.00.12 and prior, CC32XX SDK v4.30.00.06 and prior, CC13X0 SDK versions prior to v4.10.03, CC13X2 and CC26XX SDK versions prior to v4.40.00, CC3200 SDK v1.5.0 and prior, CC3100 SDK v1.3.0 and prior). | ||||
| CVE-2021-22676 | 1 Advantech | 1 Webaccess\/scada | 2024-11-21 | 6.1 Medium |
| UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1). | ||||
| CVE-2021-22675 | 1 Ti | 7 Cc3100 Software Development Kit, Cc3200 Software Development Kit, Simplelink Cc13x0 Software Development Kit and 4 more | 2024-11-21 | 7.2 High |
| The affected product is vulnerable to integer overflow while parsing malformed over-the-air firmware update files, which may allow an attacker to remotely execute code on SimpleLink Wi-Fi (MSP432E4 SDK: v4.20.00.12 and prior, CC32XX SDK v4.30.00.06 and prior, CC13X0 SDK versions prior to v4.10.03, CC13X2 and CC26XX SDK versions prior to v4.40.00, CC3200 SDK v1.5.0 and prior, CC3100 SDK v1.3.0 and prior). | ||||
| CVE-2021-22674 | 1 Advantech | 1 Webaccess\/scada | 2024-11-21 | 6.5 Medium |
| The affected product is vulnerable to a relative path traversal condition, which may allow an attacker access to unauthorized files and directories on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1). | ||||
| CVE-2021-22673 | 1 Ti | 7 Cc3100 Software Development Kit, Cc3200 Software Development Kit, Simplelink Cc13x0 Software Development Kit and 4 more | 2024-11-21 | 8.0 High |
| The affected product is vulnerable to stack-based buffer overflow while processing over-the-air firmware updates from the CDN server, which may allow an attacker to remotely execute code on the SimpleLink Wi-Fi (MSP432E4 SDK: v4.20.00.12 and prior, CC32XX SDK v4.30.00.06 and prior, CC13X0 SDK versions prior to v4.10.03, CC13X2 and CC26XX SDK versions prior to v4.40.00, CC3200 SDK v1.5.0 and prior, CC3100 SDK v1.3.0 and prior). | ||||
| CVE-2021-22672 | 1 Deltaww | 1 Cncsoft Screeneditor | 2024-11-21 | 7.8 High |
| Delta Electronics' CNCSoft ScreenEditor in versions prior to v1.01.30 could allow the corruption of data, a denial-of-service condition, or code execution. The vulnerability may allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2021-22671 | 1 Ti | 7 Cc3100 Software Development Kit, Cc3200 Software Development Kit, Simplelink Cc13x0 Software Development Kit and 4 more | 2024-11-21 | 9.8 Critical |
| Multiple integer overflow issues exist while processing long domain names, which may allow an attacker to remotely execute code on the SimpleLink Wi-Fi (MSP432E4 SDK: v4.20.00.12 and prior, CC32XX SDK v4.30.00.06 and prior, CC13X0 SDK versions prior to v4.10.03, CC13X2 and CC26XX SDK versions prior to v4.40.00, CC3200 SDK v1.5.0 and prior, CC3100 SDK v1.3.0 and prior). | ||||
| CVE-2021-22670 | 1 Fatek | 1 Fvdesigner | 2024-11-21 | 7.8 High |
| An uninitialized pointer may be exploited in Fatek FvDesigner Version 1.5.76 and prior while the application is processing project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. | ||||