Export limit exceeded: 374426 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (374426 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-22828 | 1 Synametrics | 1 Synaman | 2024-11-21 | 7.5 High |
| An insecure direct object reference for the file-download URL in Synametrics SynaMan before 5.0 allows a remote attacker to access unshared files via a modified base64-encoded filename string. | ||||
| CVE-2022-22821 | 1 Nvidia | 1 Nemo | 2024-11-21 | 2 Low |
| NVIDIA NeMo before 1.6.0 contains a vulnerability in ASR WebApp, in which ../ Path Traversal may lead to deletion of any directory when admin privileges are available. | ||||
| CVE-2022-22820 | 1 Linecorp | 1 Line | 2024-11-21 | 5.5 Medium |
| Due to the lack of media file checks before rendering, it was possible for an attacker to cause abnormal CPU consumption for message recipient by sending specially crafted gif image in LINE for Windows before 7.4. | ||||
| CVE-2022-22819 | 1 Nxp | 12 Lpc55s66jbd100, Lpc55s66jbd100 Firmware, Lpc55s66jbd64 and 9 more | 2024-11-21 | 7.8 High |
| NXP LPC55S66JBD64, LPC55S66JBD100, LPC55S66JEV98, LPC55S69JBD64, LPC55S69JBD100, and LPC55S69JEV98 microcontrollers (ROM version 1B) have a buffer overflow in parsing SB2 updates before the signature is verified. This can allow an attacker to achieve non-persistent code execution via a crafted unsigned update. | ||||
| CVE-2022-22818 | 4 Debian, Djangoproject, Fedoraproject and 1 more | 6 Debian Linux, Django, Fedora and 3 more | 2024-11-21 | 6.1 Medium |
| The {% debug %} template tag in Django 2.2 before 2.2.27, 3.2 before 3.2.12, and 4.0 before 4.0.2 does not properly encode the current context. This may lead to XSS. | ||||
| CVE-2022-22817 | 3 Debian, Python, Redhat | 5 Debian Linux, Pillow, Enterprise Linux and 2 more | 2024-11-21 | 9.8 Critical |
| PIL.ImageMath.eval in Pillow before 9.0.0 allows evaluation of arbitrary expressions, such as ones that use the Python exec method. A lambda expression could also be used. | ||||
| CVE-2022-22816 | 3 Debian, Python, Redhat | 5 Debian Linux, Pillow, Enterprise Linux and 2 more | 2024-11-21 | 6.5 Medium |
| path_getbbox in path.c in Pillow before 9.0.0 has a buffer over-read during initialization of ImagePath.Path. | ||||
| CVE-2022-22815 | 3 Debian, Python, Redhat | 3 Debian Linux, Pillow, Enterprise Linux | 2024-11-21 | 6.5 Medium |
| path_getbbox in path.c in Pillow before 9.0.0 improperly initializes ImagePath.Path. | ||||
| CVE-2022-22814 | 1 Asus | 1 Myasus | 2024-11-21 | 9.8 Critical |
| The System Diagnosis service of MyASUS before 3.1.2.0 allows privilege escalation. | ||||
| CVE-2022-22813 | 1 Schneider-electric | 66 Easergy P141, Easergy P141 Firmware, Easergy P142 and 63 more | 2024-11-21 | 9.8 Critical |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration. | ||||
| CVE-2022-22812 | 1 Schneider-electric | 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more | 2024-11-21 | 6.1 Medium |
| A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) | ||||
| CVE-2022-22811 | 1 Schneider-electric | 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more | 2024-11-21 | 8.1 High |
| A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system�s configurations when an attacker persuades a user to visit a rogue website. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) | ||||
| CVE-2022-22810 | 1 Schneider-electric | 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more | 2024-11-21 | 9.8 Critical |
| A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) | ||||
| CVE-2022-22809 | 1 Schneider-electric | 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more | 2024-11-21 | 5.3 Medium |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) | ||||
| CVE-2022-22808 | 1 Schneider-electric | 14 Hmibscea53d1edb, Hmibscea53d1edb Firmware, Hmibscea53d1edl and 11 more | 2024-11-21 | 8.8 High |
| A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13) | ||||
| CVE-2022-22807 | 1 Schneider-electric | 14 Hmibscea53d1edb, Hmibscea53d1edb Firmware, Hmibscea53d1edl and 11 more | 2024-11-21 | 7.4 High |
| A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13) | ||||
| CVE-2022-22806 | 1 Schneider-electric | 16 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 13 more | 2024-11-21 | 9.8 Critical |
| A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior) | ||||
| CVE-2022-22805 | 1 Schneider-electric | 16 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 13 more | 2024-11-21 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior) | ||||
| CVE-2022-22804 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-11-21 | 5.4 Medium |
| A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior) | ||||
| CVE-2022-22798 | 1 Sysaid | 1 Sysaid | 2024-11-21 | 6.8 Medium |
| Sysaid – Pro Plus Edition, SysAid Help Desk Broken Access Control v20.4.74 b10, v22.1.20 b62, v22.1.30 b49 - An attacker needs to log in as a guest after that the system redirects him to the service portal or EndUserPortal.JSP, then he needs to change the path in the URL to /ConcurrentLogin%2ejsp after that he will receive an error message with a login button, by clicking on it, he will connect to the system dashboard. The attacker can receive sensitive data like server details, usernames, workstations, etc. He can also perform actions such as uploading files, deleting calls from the system. | ||||