Export limit exceeded: 374421 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (374421 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-24320 | 1 Schneider-electric | 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-11-21 | 5.9 Medium |
| A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) | ||||
| CVE-2022-24319 | 1 Schneider-electric | 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-11-21 | 5.9 Medium |
| A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) | ||||
| CVE-2022-24318 | 1 Schneider-electric | 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2024-11-21 | 7.5 High |
| A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions) | ||||
| CVE-2022-24317 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 7.5 High |
| A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24316 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 7.5 High |
| A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24315 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 7.5 High |
| A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24314 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 7.5 High |
| A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24313 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24312 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 9.8 Critical |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24311 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 9.8 Critical |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24310 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2024-11-21 | 9.8 Critical |
| A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | ||||
| CVE-2022-24308 | 4 Apple, Automox, Linux and 1 more | 4 Macos, Automox, Linux Kernel and 1 more | 2024-11-21 | 5.5 Medium |
| Automox Agent prior to version 37 on Windows and Linux and Version 36 on OSX could allow for a non privileged user to obtain sensitive information during the install process. | ||||
| CVE-2022-24307 | 1 Joinmastodon | 1 Mastodon | 2024-11-21 | 9.8 Critical |
| Mastodon before 3.3.2 and 3.4.x before 3.4.6 has incorrect access control because it does not compact incoming signed JSON-LD activities. (JSON-LD signing has been supported since version 1.6.0.) | ||||
| CVE-2022-24306 | 1 Zohocorp | 1 Manageengine Sharepoint Manager Plus | 2024-11-21 | 9.8 Critical |
| Zoho ManageEngine SharePoint Manager Plus before 4329 allows account takeover because authorization is mishandled. | ||||
| CVE-2022-24305 | 1 Zohocorp | 1 Manageengine Sharepoint Manager Plus | 2024-11-21 | 9.8 Critical |
| Zoho ManageEngine SharePoint Manager Plus before 4329 is vulnerable to a sensitive data leak that leads to privilege escalation. | ||||
| CVE-2022-24303 | 2 Fedoraproject, Python | 2 Fedora, Pillow | 2024-11-21 | 9.1 Critical |
| Pillow before 9.0.1 allows attackers to delete files because spaces in temporary pathnames are mishandled. | ||||
| CVE-2022-24301 | 2 Debian, Minetest | 2 Debian Linux, Minetest | 2024-11-21 | 6.5 Medium |
| In Minetest before 5.4.0, players can add or subtract items from a different player's inventory. | ||||
| CVE-2022-24300 | 2 Debian, Minetest | 2 Debian Linux, Minetest | 2024-11-21 | 9.8 Critical |
| Minetest before 5.4.0 allows attackers to add or modify arbitrary meta fields of the same item stack as saved user input, aka ItemStack meta injection. | ||||
| CVE-2022-24299 | 1 Netgate | 2 Pfsense, Pfsense Plus | 2024-11-21 | 8.8 High |
| Improper input validation vulnerability in pfSense CE and pfSense Plus (pfSense CE software versions prior to 2.6.0 and pfSense Plus software versions prior to 22.01) allows a remote attacker with the privilege to change OpenVPN client or server settings to execute an arbitrary command. | ||||
| CVE-2022-24296 | 1 Mitsubishi | 40 Ae-200a, Ae-200a Firmware, Ae-200e and 37 more | 2024-11-21 | 7.5 High |
| Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications. | ||||