Export limit exceeded: 363785 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (363785 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2013-2793 | 1 Trianglemicroworks | 3 .net Communication Protocol Components, Ansi C Source Code Libraries, Scada Data Gateway | 2025-04-11 | N/A |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. | ||||
| CVE-2013-2794 | 1 Trianglemicroworks | 3 .net Communication Protocol Components, Ansi C Source Code Libraries, Scada Data Gateway | 2025-04-11 | N/A |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. | ||||
| CVE-2013-2796 | 1 Schneider-electric | 3 Citectscada, Powerlogic Scada, Vijeo Citect | 2025-04-11 | N/A |
| Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | ||||
| CVE-2013-2798 | 1 Selinc | 4 Sel-2241, Sel-3505, Sel-3530 and 1 more | 2025-04-11 | N/A |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. | ||||
| CVE-2013-2800 | 1 Osisoft | 1 Pi Interface | 2025-04-11 | N/A |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (memory consumption or memory corruption, instance shutdown, and data-collection outage) via crafted C37.118 configuration packets. | ||||
| CVE-2013-2801 | 1 Osisoft | 1 Pi Interface | 2025-04-11 | N/A |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (instance shutdown and data-collection outage) via crafted C37.118 configuration packets that trigger an invalid read operation. | ||||
| CVE-2013-2802 | 1 Sixnet | 2 Rtu Firmware, Udr | 2025-04-11 | N/A |
| The universal protocol implementation in Sixnet UDR before 2.0 and RTU firmware before 4.8 allows remote attackers to execute arbitrary code; read, modify, or create files; or obtain file metadata via function opcodes. | ||||
| CVE-2013-2803 | 1 Prosoft-technology | 1 Radiolinx Controlscape | 2025-04-11 | N/A |
| ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force attack. | ||||
| CVE-2013-2804 | 1 Softwaretoolbox | 1 Top Server | 2025-04-11 | N/A |
| The DNP Master Driver in Software Toolbox TOP Server before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. | ||||
| CVE-2013-2808 | 1 Philips | 4 Xper Flex Cardio, Xper Information Management Physiomonitoring 5, Xper Information Management Vascular Monitoring 5 and 1 more | 2025-04-11 | N/A |
| Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000. | ||||
| CVE-2013-2833 | 1 Google | 1 Chrome Os | 2025-04-11 | N/A |
| Use-after-free vulnerability in the O3D plug-in in Google Chrome OS before 26.0.1410.57 allows remote attackers to cause a denial of service or possibly have unspecified other impact via vectors related to improper management of ownership relationships involving Elements and DrawElements. | ||||
| CVE-2013-2811 | 2 Catapultsoftware, Ge | 4 Catapult Dnp3 I\/o Driver, Intelligent Platforms Proficy Dnp3 I\/o Driver, Intelligent Platforms Proficy Hmi\/scada Cimplicity and 1 more | 2025-04-11 | N/A |
| The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. | ||||
| CVE-2013-2813 | 1 Cooperindustries | 3 Smp 16 Gateway \(data Concentrator\), Smp 4\/dp Gateway \(data Concentrator\), Smp 4 Gateway \(data Concentrator\) | 2025-04-11 | N/A |
| The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows remote attackers to cause a denial of service (reboot or link outage) via a crafted DNP3 TCP packet. | ||||
| CVE-2013-2814 | 1 Cooperindustries | 1 Dnp3 Master Opc Server | 2025-04-11 | N/A |
| Cooper Power Systems Cybectec DNP3 Master OPC Server allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors. | ||||
| CVE-2013-2816 | 1 Cooperindustries | 3 Smp 16 Gateway \(data Concentrator\), Smp 4\/dp Gateway \(data Concentrator\), Smp 4 Gateway \(data Concentrator\) | 2025-04-11 | N/A |
| The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows physically proximate attackers to cause a denial of service (reboot or link outage) via crafted input over a serial line. | ||||
| CVE-2013-2817 | 1 Mitsubishielectric | 1 Mc-worx Suite | 2025-04-11 | N/A |
| An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click. | ||||
| CVE-2013-2818 | 1 Alstom | 1 E-terracontrol | 2025-04-11 | N/A |
| The DNP Master Driver in Alstom e-terracontrol 3.5, 3.6, and 3.7 allows physically proximate attackers to cause a denial of service (infinite loop and DNP3 service disruption) via crafted input over a serial line. | ||||
| CVE-2013-2819 | 1 Sierrawireless | 19 Airlink Mp At\&t, Airlink Mp At\&t Wifi, Airlink Mp Bell and 16 more | 2025-04-11 | N/A |
| The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to install Trojan horse firmware by leveraging cleartext credentials in a crafted (1) update or (2) reprogramming action. | ||||
| CVE-2013-2820 | 1 Sierrawireless | 19 Airlink Mp At\&t, Airlink Mp At\&t Wifi, Airlink Mp Bell and 16 more | 2025-04-11 | N/A |
| The Sierra Wireless AirLink Raven X EV-DO gateway 4221_4.0.11.003 and 4228_4.0.11.003 allows remote attackers to reprogram the firmware via a replay attack using UDP ports 17336 and 17388. | ||||
| CVE-2013-2821 | 1 Novatech | 6 Orion5 Dnp Master, Orion5 Dnp Slave, Orion5r Dnp Master and 3 more | 2025-04-11 | N/A |
| NovaTech Orion Substation Automation Platform OrionLX DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier and Orion5/Orion5r DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier allow remote attackers to cause a denial of service (driver crash and process restart) via a crafted DNP3 TCP packet. | ||||