Search
Search Results (8 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-90880 | 1 D-link | 1 Dsl-3782 | 2026-09-15 | 7.4 High |
| A security flaw has been discovered in D-Link DSL-3782 2016-07-28. This issue affects the function system of the file /cgi-bin/New_GUI/Set/Diagnostics.asp of the component Diagnostics. Performing a manipulation of the argument Addr results in command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. | ||||
| CVE-2018-8941 | 2 D-link, Dlink | 2 Dsl-3782 Firmware, Dsl-3782 | 2024-11-21 | N/A |
| Diagnostics functionality on D-Link DSL-3782 devices with firmware EU v. 1.01 has a buffer overflow, allowing authenticated remote attackers to execute arbitrary code via a long Addr value to the 'set Diagnostics_Entry' function in an HTTP request, related to /userfs/bin/tcapi. | ||||
| CVE-2018-10750 | 2 D-link, Dlink | 2 Dsl-3782 Firmware, Dsl-3782 | 2024-11-21 | N/A |
| An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'staticGet' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'staticGet <node_name attr>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code. | ||||
| CVE-2018-10749 | 2 D-link, Dlink | 2 Dsl-3782 Firmware, Dsl-3782 | 2024-11-21 | N/A |
| An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'commit' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'commit <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code. | ||||
| CVE-2018-10748 | 2 D-link, Dlink | 2 Dsl-3782 Firmware, Dsl-3782 | 2024-11-21 | N/A |
| An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'show' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'show <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code. | ||||
| CVE-2018-10747 | 2 D-link, Dlink | 2 Dsl-3782 Firmware, Dsl-3782 | 2024-11-21 | N/A |
| An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as an 'unset' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'unset <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code. | ||||
| CVE-2018-10746 | 2 D-link, Dlink | 2 Dsl-3782 Firmware, Dsl-3782 | 2024-11-21 | N/A |
| An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'get' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'get <node_name attr>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code. | ||||
| CVE-2018-10713 | 2 D-link, Dlink | 2 Dsl-3782 Firmware, Dsl-3782 | 2024-11-21 | N/A |
| An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'read' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'read <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code. | ||||
Page 1 of 1.