| The ReadVIFFImage function in coders/viff.c in ImageMagick 7.0.6-6 allows remote attackers to cause a denial of service (memory consumption) via a crafted VIFF file. |
| A Cross-Site Request Forgery (CSRF) issue was discovered in Westermo MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The application does not verify whether a request was intentionally provided by the user, making it possible for an attacker to trick a user into making a malicious request to the server. |
| The L2TP Client in MikroTik RouterOS versions 6.83.3 and 6.37.4 does not enable IPsec encryption after a reboot, which allows man-in-the-middle attackers to view transmitted data unencrypted and gain access to networks on the L2TP server by monitoring the packets for the transmitted data and obtaining the L2TP secret. |
| A heap-based buffer overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities where there is a lack of proper validation of the length of user-supplied data prior to copying it to the heap-based buffer, which could allow an attacker to execute arbitrary code under the context of the process. |
| An issue was discovered in ytnef before 1.9.1. This is related to a patch described as "8 of 9. Out of Bounds read and write." |
| A SQL Injection issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. By submitting a specially crafted parameter, it is possible to inject arbitrary SQL statements that could allow an attacker to obtain sensitive information. |
| An Uncontrolled Search Path Element issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A maliciously crafted dll file placed earlier in the search path may allow an attacker to execute code within the context of the application. |
| An issue was discovered in tnef before 1.4.13. Four type confusions have been identified in the file_add_mapi_attrs() function. These might lead to invalid read and write operations, controlled by an attacker. |
| Integer overflow in io-ico.c in gdk-pixbuf allows context-dependent attackers to cause a denial of service (segmentation fault and application crash) via a crafted image entry offset in an ICO file, which triggers an out-of-bounds read, related to compiler optimizations. |
| A SQL Injection issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. The application is vulnerable to injection of malicious SQL queries via the input from the client. |
| The dex_parse_debug_item function in libr/bin/p/bin_dex.c in radare2 1.2.1 allows remote attackers to cause a denial of service (buffer overflow and application crash) or possibly have unspecified other impact via a crafted DEX file. |
| A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution. |
| A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges. |
| A remote command injection vulnerability exists in the Barracuda Load Balancer product line (confirmed on v5.4.0.004 (2015-11-26) and v6.0.1.006 (2016-08-19); fixed in 6.1.0.003 (2017-01-17)) in which an authenticated user can execute arbitrary shell commands and gain root privileges. The vulnerability stems from unsanitized data being processed in a system call when the delete_assessment command is issued. |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks. |
| The Symantec Messaging Gateway can encounter a file inclusion vulnerability, which is a type of vulnerability that is most commonly found to affect web applications that rely on a scripting run time. This issue is caused when an application builds a path to executable code using an attacker-controlled variable in a way that allows the attacker to control which file is executed at run time. This file inclusion vulnerability subverts how an application loads code for execution. Successful exploitation of a file inclusion vulnerability will result in remote code execution on the web server that runs the affected web application. |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. |
| The Symantec Messaging Gateway before 10.6.3-267 can encounter an issue of cross site request forgery (also known as one-click attack and is abbreviated as CSRF or XSRF), which is a type of malicious exploit of a website where unauthorized commands are transmitted from a user that the web application trusts. A CSRF attack attempts to exploit the trust that a specific website has in a user's browser. |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link. |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. |