| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| HIWIN Robot System Software version 3.3.21.9869 does not properly address the terminated command source. As a result, an attacker could craft code to disconnect HRSS and the controller and cause a denial-of-service condition. |
| Fuji Electric D300win prior to version 3.7.1.17 is vulnerable to a write-what-where condition, which could allow an attacker to overwrite program memory to manipulate the flow of information. |
| CWE-302 Authentication Bypass by Assumed-Immutable Data in AliveCor Kardia App version 5.17.1-754993421 and prior
on Android allows an unauthenticated attacker with physical access to the Android device containing the app to bypass application authentication and alter information in the app. |
|
The physical IoT device of the AliveCor's KardiaMobile, a smartphone-based personal electrocardiogram (EKG) has no encryption for its data-over-sound protocols. Exploiting this vulnerability could allow an attacker to read patient EKG results or create a denial-of-service condition by emitting sounds at similar frequencies as the device, disrupting the smartphone microphone’s ability to accurately read the data. To carry out this attack, the attacker must be close (less than 5 feet) to pick up and emit sound waves.
|
|
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can remotely overflow the stack buffer and enable remote code execution.
|
|
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can use an outsized filename to overflow the stack buffer and enable remote code execution.
|
|
Advantech R-SeeNet Versions 2.4.19 and prior are vulnerable to path traversal attacks. An unauthorized attacker could remotely exploit vulnerable PHP code to delete .PDF files.
|
| Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to relative path traversal, which may allow an attacker access to unauthorized files and directories. |
| Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to improper neutralization of special elements in output, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition. |
| Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to unrestricted file uploads, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition. |
| Authentication is currently unsupported in Haas Controller version 100.20.000.1110 when using the “Ethernet Q Commands” service, which allows any user on the same network segment as the controller (even while connected remotely) to access the service and write unauthorized macros to the device. |
| Haas Controller version 100.20.000.1110 has insufficient granularity of access control when using the "Ethernet Q Commands" service. Any user is able to write macros into registers outside of the authorized accessible range. This could allow a user to access privileged resources or resources out of context. |
| Communication traffic involving "Ethernet Q Commands" service of Haas Controller version 100.20.000.1110 is transmitted in cleartext. This allows an attacker to obtain sensitive information being passed to and from the controller. |
| Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host Engineering H0-ECOM100 Communications Module Firmware versions v5.0.155 and prior. This may allow an attacker to crash the affected device or cause it to become unresponsive. |
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
|
|
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
|
|
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
|
|
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
|
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
|
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
|