Export limit exceeded: 372359 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (372359 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-2004 | 1 Automationdirect | 18 D0-06aa, D0-06aa Firmware, D0-06ar and 15 more | 2025-04-16 | 7.5 High |
| AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72; | ||||
| CVE-2022-2044 | 1 Moxa | 2 Nport 5110, Nport 5110 Firmware | 2025-04-16 | 8.2 High |
| MOXA NPort 5110: Firmware Versions 2.10 is vulnerable to an out-of-bounds write that may allow an attacker to overwrite values in memory, causing a denial-of-service condition or potentially bricking the device. | ||||
| CVE-2022-2043 | 1 Moxa | 2 Nport 5110, Nport 5110 Firmware | 2025-04-16 | 7.5 High |
| MOXA NPort 5110: Firmware Versions 2.10 is vulnerable to an out-of-bounds write that can cause the device to become unresponsive. | ||||
| CVE-2022-2898 | 1 Measuresoft | 2 Scadapro Client, Scadapro Server | 2025-04-16 | 6.1 Medium |
| Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition. | ||||
| CVE-2022-1368 | 1 Cognex | 2 3d-a1000 Dimensioning System, 3d-a1000 Dimensioning System Firmware | 2025-04-16 | 9.8 Critical |
| The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account. | ||||
| CVE-2022-1522 | 1 Cognex | 2 3d-a1000 Dimensioning System, 3d-a1000 Dimensioning System Firmware | 2025-04-16 | 5.3 Medium |
| The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics. | ||||
| CVE-2022-1525 | 1 Cognex | 2 3d-a1000 Dimensioning System, 3d-a1000 Dimensioning System Firmware | 2025-04-16 | 9.1 Critical |
| The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code of password protected web elements. | ||||
| CVE-2022-38100 | 1 Contechealth | 2 Cms8000, Cms8000 Firmware | 2025-04-16 | 7.5 High |
| The CMS800 device fails while attempting to parse malformed network data sent by a threat actor. A threat actor with network access can remotely issue a specially formatted UDP request that will cause the entire device to crash and require a physical reboot. A UDP broadcast request could be sent that causes a mass denial-of-service attack on all CME8000 devices connected to the same network. | ||||
| CVE-2022-38069 | 1 Contechealth | 2 Cms8000, Cms8000 Firmware | 2025-04-16 | 4.3 Medium |
| Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters | ||||
| CVE-2022-3027 | 1 Contechealth | 2 Cms8000, Cms8000 Firmware | 2025-04-16 | 5.7 Medium |
| The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information. | ||||
| CVE-2022-38453 | 1 Contechealth | 2 Cms8000, Cms8000 Firmware | 2025-04-16 | 3 Low |
| Multiple binary application files on the CMS8000 device are compiled with 'not stripped' and 'debug_info' compilation settings. These compiler settings greatly decrease the level of effort for a threat actor to reverse engineer sensitive code and identify additional vulnerabilities. | ||||
| CVE-2022-2332 | 1 Honeywell | 1 Softmaster | 2025-04-16 | 6.2 Medium |
| A local unprivileged attacker may escalate to administrator privileges in Honeywell SoftMaster version 4.51, due to insecure permission assignment. | ||||
| CVE-2022-2973 | 1 Mz-automation | 1 Libiec61850 | 2025-04-16 | 8.6 High |
| MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) uses a NULL pointer in certain situations. which could allow an attacker to crash the server. | ||||
| CVE-2022-2971 | 1 Mz-automation | 1 Libiec61850 | 2025-04-16 | 8.6 High |
| MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) accesses a resource using an incompatible type, which could allow an attacker to crash the server with a malicious payload. | ||||
| CVE-2022-2972 | 1 Mz-automation | 1 Libiec61850 | 2025-04-16 | 10 Critical |
| MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) is vulnerable to a stack-based buffer overflow, which could allow an attacker to crash the device or remotely execute arbitrary code. | ||||
| CVE-2022-2970 | 1 Mz-automation | 1 Libiec61850 | 2025-04-16 | 10 Critical |
| MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) does not sanitize input before memcpy is used, which could allow an attacker to crash the device or remotely execute arbitrary code. | ||||
| CVE-2022-38138 | 1 Trianglemicroworks | 2 Iec 60870-6 Software Library, Iec 61850 Software Library | 2025-04-16 | 7.5 High |
| The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition. | ||||
| CVE-2021-22685 | 1 Cassianetworks | 1 Access Controller | 2025-04-16 | 6.2 Medium |
| An attacker may be able to use minify route with a relative path to view any file on the Cassia Networks Access Controller prior to 2.0.1. | ||||
| CVE-2022-3382 | 1 Hiwin | 1 Robot System Software | 2025-04-16 | 7.5 High |
| HIWIN Robot System Software version 3.3.21.9869 does not properly address the terminated command source. As a result, an attacker could craft code to disconnect HRSS and the controller and cause a denial-of-service condition. | ||||
| CVE-2022-1523 | 1 Fujielectric | 1 D300win | 2025-04-16 | 6.1 Medium |
| Fuji Electric D300win prior to version 3.7.1.17 is vulnerable to a write-what-where condition, which could allow an attacker to overwrite program memory to manipulate the flow of information. | ||||