| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When receiving an OpenPGP/MIME signed email message that contains an additional outer MIME message layer, for example a message footer added by a mailing list gateway, Thunderbird only considered the inner signed message for the signature validity. This gave the false impression that the additional contents were also covered by the digital signature. Starting with Thunderbird version 91.4.1, only the signature that belongs to the top level MIME part will be considered for the displayed status. This vulnerability affects Thunderbird < 91.4.1. |
| A Stored Cross-site scripting (XSS) vulnerability via MAster.php in Sourcecodetester Simple Client Management System (SCMS) 1.0 allows remote attackers to inject arbitrary web script or HTML via the vulnerable input fields. |
| An OAuth session fixation vulnerability existed in the VPN login flow, where an attacker could craft a custom login URL, convince a VPN user to login via that URL, and obtain authenticated access as that user. This issue is limited to cases where attacker and victim are sharing the same source IP and could allow the ability to view session states and disconnect VPN sessions. This vulnerability affects Mozilla VPN iOS 1.0.7 < (929), Mozilla VPN Windows < 1.2.2, and Mozilla VPN Android 1.1.0 < (1360). |
| The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object reference vulnerability on endpoint and parameter device IDs, which accept arbitrary device IDs without further verification. |
| SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication. |
| The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object references vulnerability on endpoint and POST parameter “Device ID,” which accepts arbitrary device IDs. |
| The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner’s mobile number. |
| The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code. |
| The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks. |
| The affected product is vulnerable to two SQL injections that require high privileges for exploitation and may allow an unauthorized attacker to disclose information |
| The affected product is vulnerable to directory traversal, which may allow an attacker to access unauthorized files and execute arbitrary code. |
| The affected product is vulnerable due to missing authentication, which may allow an attacker to read or modify sensitive data and execute arbitrary code, resulting in a denial-of-service condition. |
| The affected product is vulnerable to multiple SQL injections, which may allow an unauthorized attacker to disclose information. |
| The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code. |
| Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup. |
| An attacker may be able to execute malicious actions due to the lack of device access protections and device permissions when using the web application. This could lead to uploading python files which can be later executed. |
| A crafted HTTP packet without a content-type header can create a denial-of-service condition in Softing Secure Integration Server V1.22. |
| Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the `admin` password. There is no warning or prompt to ask the user to change the default password, and to change the password, many steps are required. |
| Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, and uaGate are affected by a NULL pointer dereference vulnerability. |
| A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22. |