| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online. |
| The affected products are vulnerable of untrusted data due to deserialization without prior authorization/authentication, which may allow an attacker to remotely execute arbitrary code. |
| The affected products are vulnerable to directory traversal, which may allow an attacker to obtain arbitrary operating system files. |
| A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings. |
| A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host. |
| LRM utilizes elevated privileges. An unauthenticated malicious actor can upload and execute code remotely at the operating system level, which can allow an attacker to change settings, configurations, software, or access sensitive data on the affected produc. An attacker could also exploit this vulnerability to access APIs not intended for general use and interact through the network. |
| LRM does not restrict the types of files that can be uploaded to the affected product. A malicious actor can upload any file type, including executable code that allows for a remote code exploit. |
| LRM contains a directory traversal vulnerability that can allow a malicious actor to upload outside the intended directory structure. |
| LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data. |
| An attacker with weak credentials could access the TCP port via an open FTP port, allowing an attacker to read sensitive files and write to remotely executable directories. |
| The default password for the web application’s root user (the vendor’s private account) was weak and the MD5 hash was used to crack the password using a widely available open-source tool. |
| Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC (e.g., from the browser console) or by loading the corresponding, browser accessible PHP script |
| Client-side JavaScript controls may be bypassed to change user credentials and permissions without authentication, including a “root” user level meant only for the vendor. Web server root level access allows for changing of safety critical parameters. |
| Weak default root user credentials allow remote attackers to easily obtain OS superuser privileges over the open TCP port for SSH. |
| Controls limiting uploads to certain file extensions may be bypassed. This could allow an attacker to intercept the initial file upload page response and modify the associated code. This modified code can be forwarded and used by a script loaded later in the sequence, allowing for arbitrary file upload into a location where PHP scripts may be executed. |
| An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0. |
| Elcomplus SmartICS v2.3.4.0 does not validate the filenames sufficiently, which enables authenticated administrator-level users to perform path traversal attacks and specify arbitrary files. |
| By using a specific credential string, an attacker with network access to the device’s web interface could circumvent the authentication scheme and perform administrative operations. |
| A user with administrative privileges in Distributed Data Systems WebHMI 4.1.1.7662 can store a script that could impact other logged in users. |
| An issue in the firmware update process of TP-LINK TL-WA801N / TL-WA801ND V1 v3.12.16 and earlier allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via uploading a crafted firmware image. |