| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A malicious actor having access to the exported configuration file may obtain the stored credentials and thereby gain access to the protected resource. If the same passwords were used for other resources, further such assets may be compromised. |
| Hills ComNav version 3002-19 suffers from a weak communication channel. Traffic across the local network for the configuration pages can be viewed by a malicious actor. The size of certain communications packets are predictable. This would allow an attacker to learn the state of the system if they can observe the traffic. This would be possible even if the traffic were encrypted, e.g., using WPA2, as the packet sizes would remain observable. The communication encryption scheme is theoretically sound, but is not strong enough for the level of protection required. |
| There is no limit to the number of attempts to authenticate for the local configuration pages for the Hills ComNav Version 3002-19 interface, which allows local attackers to brute-force credentials. |
| All versions of Uffizio GPS Tracker may allow an attacker to perform unintended actions on behalf of a user. |
| An attacker may be able to inject client-side JavaScript code on multiple instances within all versions of Uffizio GPS Tracker. |
| Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate download requests, enabling malicious users to perform path traversal attacks and potentially download arbitrary files from the system. |
| Elcomplus SmartPTT is vulnerable as the backup and restore system does not adequately validate upload requests, enabling a malicious user to potentially upload arbitrary files. |
| Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerChart.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegIND. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadREGbyID. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegf. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. |
| In four instances DMARS (All versions prior to v2.1.10.24) does not properly restrict references of XML external entities while processing specific project files, which may allow unauthorized information disclosure. |