| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An attacker can take leverage on PerFact OpenVPN-Client versions 1.4.1.0 and prior to send the config command from any application running on the local host machine to force the back-end server into initializing a new open-VPN instance with arbitrary open-VPN configuration. This could result in the attacker achieving execution with privileges of a SYSTEM user. |
| Fuji Electric D300win prior to version 3.7.1.17 is vulnerable to an out-of-bounds read, which could allow an attacker to leak sensitive data from the process memory. |
| The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API. |
| The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API. |
|
Horner Automation's Cscape version 9.90 SP7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by writing outside the memory buffer.
|
|
Horner Automation's Cscape version 9.90 SP 7 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory write.
|
| Horner Automation's Cscape version 9.90 SP 6 and prior does not properly validate user-supplied data. If a user opens a maliciously formed FNT file, then an attacker could execute arbitrary code within the current process by accessing an uninitialized pointer, leading to an out-of-bounds memory read.
|
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
|
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
|
| SAUTER Controls moduWeb firmware version 2.7.1 is vulnerable to reflective cross-site scripting (XSS). The web application does not adequately sanitize request strings of malicious JavaScript. An attacker utilizing XSS could then execute malicious code in users’ browsers and steal sensitive information, including user credentials. |
| All versions of ETIC Telecom Remote Access Server (RAS) 4.5.0 and prior’s web portal is vulnerable to accepting malicious firmware packages that could provide a backdoor to an attacker and provide privilege escalation to the device. |
| SQL Injection in
AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network |
| SQL Injection in
FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network |