Search

Search Results (372138 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-2898 1 Measuresoft 2 Scadapro Client, Scadapro Server 2025-04-16 6.1 Medium
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition.
CVE-2022-1368 1 Cognex 2 3d-a1000 Dimensioning System, 3d-a1000 Dimensioning System Firmware 2025-04-16 9.8 Critical
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
CVE-2022-1522 1 Cognex 2 3d-a1000 Dimensioning System, 3d-a1000 Dimensioning System Firmware 2025-04-16 5.3 Medium
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.
CVE-2022-1525 1 Cognex 2 3d-a1000 Dimensioning System, 3d-a1000 Dimensioning System Firmware 2025-04-16 9.1 Critical
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-602: Client-Side Enforcement of Server-Side Security, which could allow attackers to bypass web access controls by inspecting and modifying the source code of password protected web elements.
CVE-2022-38100 1 Contechealth 2 Cms8000, Cms8000 Firmware 2025-04-16 7.5 High
The CMS800 device fails while attempting to parse malformed network data sent by a threat actor. A threat actor with network access can remotely issue a specially formatted UDP request that will cause the entire device to crash and require a physical reboot. A UDP broadcast request could be sent that causes a mass denial-of-service attack on all CME8000 devices connected to the same network.
CVE-2022-38069 1 Contechealth 2 Cms8000, Cms8000 Firmware 2025-04-16 4.3 Medium
Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters
CVE-2022-3027 1 Contechealth 2 Cms8000, Cms8000 Firmware 2025-04-16 5.7 Medium
The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information.
CVE-2022-38453 1 Contechealth 2 Cms8000, Cms8000 Firmware 2025-04-16 3 Low
Multiple binary application files on the CMS8000 device are compiled with 'not stripped' and 'debug_info' compilation settings. These compiler settings greatly decrease the level of effort for a threat actor to reverse engineer sensitive code and identify additional vulnerabilities.
CVE-2022-2332 1 Honeywell 1 Softmaster 2025-04-16 6.2 Medium
A local unprivileged attacker may escalate to administrator privileges in Honeywell SoftMaster version 4.51, due to insecure permission assignment.
CVE-2022-2973 1 Mz-automation 1 Libiec61850 2025-04-16 8.6 High
MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) uses a NULL pointer in certain situations. which could allow an attacker to crash the server.
CVE-2022-2971 1 Mz-automation 1 Libiec61850 2025-04-16 8.6 High
MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) accesses a resource using an incompatible type, which could allow an attacker to crash the server with a malicious payload.
CVE-2022-2972 1 Mz-automation 1 Libiec61850 2025-04-16 10 Critical
MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) is vulnerable to a stack-based buffer overflow, which could allow an attacker to crash the device or remotely execute arbitrary code.
CVE-2022-2970 1 Mz-automation 1 Libiec61850 2025-04-16 10 Critical
MZ Automation's libIEC61850 (versions 1.4 and prior; version 1.5 prior to commit a3b04b7bc4872a5a39e5de3fdc5fbde52c09e10e) does not sanitize input before memcpy is used, which could allow an attacker to crash the device or remotely execute arbitrary code.
CVE-2022-38138 1 Trianglemicroworks 2 Iec 60870-6 Software Library, Iec 61850 Software Library 2025-04-16 7.5 High
The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition.
CVE-2021-22685 1 Cassianetworks 1 Access Controller 2025-04-16 6.2 Medium
An attacker may be able to use minify route with a relative path to view any file on the Cassia Networks Access Controller prior to 2.0.1.
CVE-2022-3382 1 Hiwin 1 Robot System Software 2025-04-16 7.5 High
HIWIN Robot System Software version 3.3.21.9869 does not properly address the terminated command source. As a result, an attacker could craft code to disconnect HRSS and the controller and cause a denial-of-service condition.
CVE-2022-1523 1 Fujielectric 1 D300win 2025-04-16 6.1 Medium
Fuji Electric D300win prior to version 3.7.1.17 is vulnerable to a write-what-where condition, which could allow an attacker to overwrite program memory to manipulate the flow of information.
CVE-2022-40703 1 Alivecor 1 Kardia 2025-04-16 5.2 Medium
CWE-302 Authentication Bypass by Assumed-Immutable Data in AliveCor Kardia App version 5.17.1-754993421 and prior on Android allows an unauthenticated attacker with physical access to the Android device containing the app to bypass application authentication and alter information in the app.
CVE-2022-41627 1 Alivecor 6 Kardiamobile, Kardiamobile 6l, Kardiamobile 6l Firmware and 3 more 2025-04-16 4.8 Medium
The physical IoT device of the AliveCor's KardiaMobile, a smartphone-based personal electrocardiogram (EKG) has no encryption for its data-over-sound protocols. Exploiting this vulnerability could allow an attacker to read patient EKG results or create a denial-of-service condition by emitting sounds at similar frequencies as the device, disrupting the smartphone microphone’s ability to accurately read the data. To carry out this attack, the attacker must be close (less than 5 feet) to pick up and emit sound waves.
CVE-2022-3385 1 Advantech 1 R-seenet 2025-04-16 9.8 Critical
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can remotely overflow the stack buffer and enable remote code execution.