CVE-2016-8344 1 Honeywell 1 Experion Process Knowledge System 2025-04-20 N/A
An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices.
CVE-2016-8347 1 Kabona Ab 1 Webdatorcentral 2025-04-20 N/A
An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. WDC does not limit authentication attempts that may allow a brute force attack method.
CVE-2016-8348 1 Emerson 1 Liebert Sitescan Web 2025-04-20 N/A
An XML External Entity (XXE) issue was discovered in Emerson Liebert SiteScan Web Version 6.5, and prior. An attacker may enter malicious input to Liebert SiteScan through a weakly configured XML parser causing the application to execute arbitrary code or disclose file contents from a server or connected network.
CVE-2016-8350 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 6.3 Medium
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY).
CVE-2016-8352 1 Schneider-electric 6 Connexium Firmware, Tcsefec23f3f20, Tcsefec23f3f21 and 3 more 2025-04-20 N/A
An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.
CVE-2016-8353 1 Osisoft 1 Pi Web Api 2015 R2 2025-04-20 N/A
An issue was discovered in OSIsoft PI Web API 2015 R2 (Version 1.5.1). There is a weakness in this product that may allow an attacker to access the PI system without the proper permissions.
CVE-2016-8354 1 Schneider-electric 1 Unity Pro 2025-04-20 N/A
An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.
CVE-2016-8355 1 Smiths-medical 1 Cadd-solis Medication Safety Software 2025-04-20 N/A
An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates.
CVE-2016-8356 1 Kabona Ab 1 Webdatorcentral 2025-04-20 N/A
An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. The web server URL inputs are not sanitized correctly, which may allow cross-site scripting vulnerabilities.
CVE-2016-8357 1 Lynxspring 1 Jenesys Bas Bridge 2025-04-20 N/A
An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. A user with read-only access can send commands to the software and the application will accept those commands. This would allow an attacker with read-only access to make changes within the application.
CVE-2016-8358 1 Smiths-medical 1 Cadd-solis Medication Safety Software 2025-04-20 N/A
An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.
CVE-2016-8359 1 Moxa 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more 2025-04-20 6.1 Medium
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING).
CVE-2016-8360 1 Moxa 1 Softcms 2025-04-20 N/A
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code.
CVE-2016-8361 1 Lynxspring 1 Jenesys Bas Bridge 2025-04-20 N/A
An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no password allowing an attacker into the system without authentication.
CVE-2016-8364 1 Ibhsoftec 1 S7-softplc 2025-04-20 N/A
An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow.
CVE-2016-8367 1 Schneider-electric 16 Magelis Gto Advanced Optimum Panel, Magelis Gto Advanced Optimum Panel Firmware, Magelis Gtu Universal Panel and 13 more 2025-04-20 5.3 Medium
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker can open multiple connections to a targeted web server and keep connections open preventing new connections from being made, rendering the web server unavailable during an attack.
CVE-2016-8368 1 Mitsubishielectric 6 Qj71e71-100, Qj71e71-100 Firmware, Qj71e71-b2 and 3 more 2025-04-20 8.6 High
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.
CVE-2016-8369 1 Lynxspring 1 Jenesys Bas Bridge 2025-04-20 N/A
An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request (CROSS-SITE REQUEST FORGERY).
CVE-2016-8377 1 Fatek 2 Plc Winproladder, Plc Winproladder Firmware 2025-04-20 8.0 High
An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution.
CVE-2016-8370 1 Mitsubishielectric 6 Qj71e71-100, Qj71e71-100 Firmware, Qj71e71-b2 and 3 more 2025-04-20 7.5 High
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.