Export limit exceeded: 372563 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (372563 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-6023 | 1 Fatek | 5 Ethernet Module Configuration Tool Cbe Firmware, Ethernet Module Configuration Tool Cbeh Firmware, Ethernet Module Configuration Tool Cm25e Firmware and 2 more | 2025-04-20 | 9.8 Critical |
| An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device. | ||||
| CVE-2017-6024 | 1 Rockwellautomation | 4 Compactlogix 5380, Compactlogix 5380 Firmware, Controllogix 5580 and 1 more | 2025-04-20 | 5.9 Medium |
| A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller. | ||||
| CVE-2017-6025 | 1 Codesys | 1 Web Server | 2025-04-20 | N/A |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. | ||||
| CVE-2017-6026 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2025-04-20 | 9.1 Critical |
| A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised. | ||||
| CVE-2017-6027 | 1 Codesys | 1 Web Server | 2025-04-20 | N/A |
| An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution. | ||||
| CVE-2017-6028 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2025-04-20 | 9.8 Critical |
| An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application. | ||||
| CVE-2017-6029 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2025-04-20 | N/A |
| A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution. | ||||
| CVE-2017-6031 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2025-04-20 | N/A |
| A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution. | ||||
| CVE-2017-6032 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2025-04-20 | N/A |
| A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. | ||||
| CVE-2017-6033 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-04-20 | N/A |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. | ||||
| CVE-2017-6036 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2025-04-20 | N/A |
| A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination. | ||||
| CVE-2017-6038 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2025-04-20 | N/A |
| A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request. | ||||
| CVE-2017-6039 | 1 Phoenixbroadband | 2 Poweragent Sc3 Bms, Poweragent Sc3 Bms Firmware | 2025-04-20 | N/A |
| A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device. | ||||
| CVE-2017-6040 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2025-04-20 | N/A |
| An Information Exposure issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. Non-sensitive information can be obtained anonymously. | ||||
| CVE-2017-6041 | 1 Marel | 44 A320, A320 Firmware, A325 and 41 more | 2025-04-20 | N/A |
| An Unrestricted Upload issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. This vulnerability allows an attacker to modify the operation and upload firmware changes without detection. | ||||
| CVE-2017-6042 | 1 Sierra Wireless | 4 Airlink Raven Xe, Airlink Raven Xe Firmware, Airlink Raven Xt and 1 more | 2025-04-20 | N/A |
| A Cross-Site Request Forgery issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Affected devices do not verify if a request was intentionally sent by the logged-in user, which may allow an attacker to trick a client into making an unintentional request to the web server that will be treated as an authentic request. | ||||
| CVE-2017-6043 | 1 Trihedral | 1 Vtscada | 2025-04-20 | N/A |
| A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available. | ||||
| CVE-2017-6044 | 1 Sierra Wireless | 4 Airlink Raven Xe, Airlink Raven Xe Firmware, Airlink Raven Xt and 1 more | 2025-04-20 | N/A |
| An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot. | ||||
| CVE-2017-6045 | 1 Trihedral | 1 Vtscada | 2025-04-20 | N/A |
| An Information Exposure issue was discovered in Trihedral VTScada Versions prior to 11.2.26. Some files are exposed within the web server application to unauthenticated users. These files may contain sensitive configuration information. | ||||
| CVE-2017-6046 | 1 Sierra Wireless | 4 Airlink Raven Xe, Airlink Raven Xe Firmware, Airlink Raven Xt and 1 more | 2025-04-20 | N/A |
| An Insufficiently Protected Credentials issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Sensitive information is insufficiently protected during transmission and vulnerable to sniffing, which could lead to information disclosure. | ||||