| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The ColorChanger::GetColorFromStack function in colorchanger.cpp in PoDoFo 0.9.5 allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted file. |
| Heap-based buffer overflow in the PoDoFo::PdfVariant::DelayedLoad function in PdfVariant.h in PoDoFo 0.9.4 allows remote attackers to have unspecified impact via a crafted file. |
| Buffer overflow in the PoDoFo::PdfParser::ReadXRefSubsection function in PdfParser.cpp in PoDoFo 0.9.4 allows remote attackers to have unspecified impact via a crafted file. |
| The PoDoFo::PdfColor::operator function in PdfColor.cpp in PoDoFo 0.9.4 allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted file. |
| The GraphicsStack::TGraphicsStackElement::SetNonStrokingColorSpace function in graphicsstack.h in PoDoFo 0.9.4 allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted file. |
| The PoDoFo::PdfVariant::DelayedLoad function in PdfVariant.h in PoDoFo 0.9.4 allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted file. |
| The PoDoFo::PdfXObject::PdfXObject function in PdfXObject.cpp in PoDoFo 0.9.5 allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted file. |
| The PoDoFo::PdfColorGray::~PdfColorGray function in PdfColor.cpp in PoDoFo 0.9.4 allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted file. |
| The jp2_cdef_destroy function in jp2_cod.c in JasPer before 2.0.13 allows remote attackers to cause a denial of service (NULL pointer dereference) via a crafted image. |
| The jas_matrix_bindsub function in jas_seq.c in JasPer 2.0.10 allows remote attackers to cause a denial of service (invalid read) via a crafted image. |
| Heap-based buffer overflow in the jpc_dec_decodepkt function in jpc_t2dec.c in JasPer 2.0.10 allows remote attackers to have unspecified impact via a crafted image. |
| The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks. |
| A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. |
| A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level. |
| An error within the "parse_tiff_ifd()" function (internal/dcraw_common.cpp) in LibRaw versions before 0.18.2 can be exploited to corrupt memory. |
| A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. |
| An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process (CP) of the RNA series module, if network access to Port 102/TCP is available and the configuration file for the CP is stored on the RNA's CPU. |
| A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the operating-system user running the web server by sending specially crafted network packets to port 443/TCP or port 80/TCP. |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions. |