| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in the /script-api/scripts/ endpoint of OpenC3 COSMOS before 6.1.0 allows attackers to execute a directory traversal. |
| An issue in the openc3-api/tables endpoint of OpenC3 COSMOS before 6.1.0 allows attackers to execute a directory traversal. |
| A credential leak in OpenC3 COSMOS before v6.0.2 allows attackers to access service credentials as environment variables stored in all containers. |
| Jira Align is vulnerable to an authorization issue. A low-privilege user can access unexpected endpoints that disclose a small amount of sensitive information. For example, a low-level user was able to modify the steps of another user's private checklist. |
| In NetX Duo version before 6.4.4, the component of Eclipse Foundation ThreadX, there was an incorrect bound check resulting it out by two out of bound read. |
| rAthena is an open-source cross-platform MMORPG server. A use-after-free vulnerability exists in the RODEX functionality of rAthena's map-server in versions prior to commit af2f3ba. An unauthenticated attacker can exploit this vulnerability via a specific attacking scenario to cause a denial of service by crashing the map-server. This issue has been patched in commit af2f3ba. There are no known workarounds aside from manually applying the patch. |
| A stored Cross-site Scripting (XSS) vulnerability affecting Issue Management in ENOVIA Collaborative Industry Innovator from Release 3DEXPERIENCE R2022x through Release 3DEXPERIENCE R2025x allows an attacker to execute arbitrary script code in user's browser session. |
| A cross-site scripting (XSS) vulnerability in OpenC3 COSMOS before v6.0.2 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the URL parameter. |
| Deserialization of Untrusted Data vulnerability in N-able N-central allows Local Execution of Code.This issue affects N-central: before 2025.3.1. |
| Improper Input Validation vulnerability in N-able N-central allows OS Command Injection.This issue affects N-central: before 2025.3.1. |
| Novi Survey before 8.9.43676 allows remote attackers to execute arbitrary code on the server in the context of the service account. This does not provide access to stored survey or response data. |
| Cross Site Scripting vulnerability in Zimbra ZCS v.8.8.15 allows a remote authenticated attacker to execute arbitrary code via a crafted script to the /h/autoSaveDraft function. |
| In Progress MOVEit Transfer before 2021.0.6 (13.0.6), 2021.1.4 (13.1.4), 2022.0.4 (14.0.4), 2022.1.5 (14.1.5), and 2023.0.1 (15.0.1), a SQL injection vulnerability has been found in the MOVEit Transfer web application that could allow an unauthenticated attacker to gain access to MOVEit Transfer's database. Depending on the database engine being used (MySQL, Microsoft SQL Server, or Azure SQL), an attacker may be able to infer information about the structure and contents of the database, and execute SQL statements that alter or delete database elements. NOTE: this is exploited in the wild in May and June 2023; exploitation of unpatched systems can occur via HTTP or HTTPS. All versions (e.g., 2020.0 and 2019x) before the five explicitly mentioned versions are affected, including older unsupported versions. |
| In NextX Duo before 6.4.4, in the HTTP client module, the network support code for Eclipse Foundation ThreadX, the parsing of HTTP header fields was missing bounds verification. A crafted server response could cause undefined behavior. |
| An arbitrary file upload vulnerability in SigningHub v8.6.8 allows attackers to execute arbitrary code via uploading a crafted PDF file. |
| A lack of rate limiting in the login mechanism of SigningHub v8.6.8 allows attackers to bypass authentication via a brute force attack. |
| IBM Aspera Faspex 4.4.2 Patch Level 1 and earlier could allow a remote attacker to execute arbitrary code on the system, caused by a YAML deserialization flaw. By sending a specially crafted obsolete API call, an attacker could exploit this vulnerability to execute arbitrary code on the system. The obsolete API call was removed in Faspex 4.4.2 PL2. IBM X-Force ID: 243512. |
| Azure RTOS USBX is a USB host, device, and on-the-go (OTG) embedded stack, that is fully integrated with Azure RTOS ThreadX. An attacker can cause remote code execution due to out of bounds write vulnerabilities in Azure RTOS USBX. The affected components include functions/processes in host and device classes, related to CDC ECM and RNDIS in RTOS v6.2.1 and below. The fixes have been included in USBX release 6.3.0. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| Azure RTOS USBX is a high-performance USB host, device, and on-the-go (OTG) embedded stack, that is fully integrated with Azure RTOS ThreadX. The case is, in [_ux_host_class_pima_read](https://github.com/azure-rtos/usbx/blob/master/common/usbx_host_classes/src/ux_host_class_pima_read.c), there is data length from device response, returned in the very first packet, and read by [L165 code](https://github.com/azure-rtos/usbx/blob/082fd9db09a3669eca3358f10b8837a5c1635c0b/common/usbx_host_classes/src/ux_host_class_pima_read.c#L165), as header_length. Then in [L178 code](https://github.com/azure-rtos/usbx/blob/082fd9db09a3669eca3358f10b8837a5c1635c0b/common/usbx_host_classes/src/ux_host_class_pima_read.c#L178), there is a “if” branch, which check the expression of “(header_length - UX_HOST_CLASS_PIMA_DATA_HEADER_SIZE) > data_length” where if header_length is smaller than UX_HOST_CLASS_PIMA_DATA_HEADER_SIZE, calculation could overflow and then [L182 code](https://github.com/azure-rtos/usbx/blob/082fd9db09a3669eca3358f10b8837a5c1635c0b/common/usbx_host_classes/src/ux_host_class_pima_read.c#L182) the calculation of data_length is also overflow, this way the later [while loop start from L192](https://github.com/azure-rtos/usbx/blob/082fd9db09a3669eca3358f10b8837a5c1635c0b/common/usbx_host_classes/src/ux_host_class_pima_read.c#L192) can move data_pointer to unexpected address and cause write buffer overflow. The fix has been included in USBX release [6.1.12](https://github.com/azure-rtos/usbx/releases/tag/v6.1.12_rel). The following can be used as a workaround: Add check of `header_length`: 1. It must be greater than `UX_HOST_CLASS_PIMA_DATA_HEADER_SIZE`. 1. It should be greater or equal to the current returned data length (`transfer_request -> ux_transfer_request_actual_length`). |
| Azure RTOS USBx is a USB host, device, and on-the-go (OTG) embedded stack, fully integrated with Azure RTOS ThreadX and available for all Azure RTOS ThreadX–supported processors. Azure RTOS USBX implementation of host support for USB CDC ECM includes an integer underflow and a buffer overflow in the `_ux_host_class_cdc_ecm_mac_address_get` function which may be potentially exploited to achieve remote code execution or denial of service. Setting mac address string descriptor length to a `0` or `1` allows an attacker to introduce an integer underflow followed (string_length) by a buffer overflow of the `cdc_ecm -> ux_host_class_cdc_ecm_node_id` array. This may allow one to redirect the code execution flow or introduce a denial of service. The fix has been included in USBX release [6.1.12](https://github.com/azure-rtos/usbx/releases/tag/v6.1.12_rel). Improved mac address string descriptor length validation to check for unexpectedly small values may be used as a workaround. |