Export limit exceeded: 369876 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (369876 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-37771 | 2 Debian, Linux | 2 Debian Linux, Linux Kernel | 2025-11-05 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: drm/amd/pm: Prevent division by zero The user can set any speed value. If speed is greater than UINT_MAX/8, division by zero is possible. Found by Linux Verification Center (linuxtesting.org) with SVACE. | ||||
| CVE-2025-36092 | 1 Ibm | 1 Cloud Pak For Business Automation | 2025-11-05 | 6.5 Medium |
| IBM Cloud Pak For Business Automation 25.0.0, 24.0.1, and 24.0.0 could allow an authenticated user to cause a denial of service due to the improper validation of input length. | ||||
| CVE-2025-36091 | 1 Ibm | 1 Cloud Pak For Business Automation | 2025-11-05 | 4.3 Medium |
| IBM Cloud Pak For Business Automation 25.0.0, 24.0.1, and 24.0.0 could allow an authenticated user to cause dashboards to become inaccessible to legitimate users due to invalid ownership assignment. | ||||
| CVE-2025-62232 | 1 Apache | 1 Apisix | 2025-11-05 | 7.5 High |
| Sensitive data exposure via logging in basic-auth leads to plaintext usernames and passwords written to error logs and forwarded to log sinks when log level is INFO/DEBUG. This creates a high risk of credential compromise through log access. It has been fixed in the following commit: https://github.com/apache/apisix/pull/12629 Users are recommended to upgrade to version 3.14, which fixes this issue. | ||||
| CVE-2025-64455 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2025-64454 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2025-64453 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2025-64452 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2025-64451 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2025-64450 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2025-64449 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2025-64448 | 2025-11-05 | N/A | ||
| Not used | ||||
| CVE-2015-3976 | 1 Ge | 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more | 2025-11-05 | N/A |
| Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier. | ||||
| CVE-2014-5419 | 1 Ge | 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more | 2025-11-05 | N/A |
| GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network. | ||||
| CVE-2014-5418 | 1 Ge | 14 Multilink Ml1200, Multilink Ml1200 Firmware, Multilink Ml1600 and 11 more | 2025-11-05 | N/A |
| GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets. | ||||
| CVE-2014-5417 | 1 Meinberg | 8 Lantime M100, Lantime M200, Lantime M300 and 5 more | 2025-11-05 | N/A |
| Cross-site scripting (XSS) vulnerability in Meinberg NTP Server firmware on LANTIME M-Series devices 6.15.019 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||||
| CVE-2014-5415 | 1 Beckhoff | 2 Embedded Pc Images, Twincat | 2025-11-05 | 9.1 Critical |
| Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components might allow remote attackers to obtain access via the (1) Windows CE Remote Configuration Tool, (2) CE Remote Display service, or (3) TELNET service. | ||||
| CVE-2014-5414 | 1 Beckhoff | 2 Embedded Pc Images, Twincat | 2025-11-05 | 9.1 Critical |
| Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components do not restrict the number of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack. | ||||
| CVE-2014-5413 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm. | ||||
| CVE-2014-5412 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account. | ||||