| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Hexagon HxGN OnCall Dispatch Advantage (Web) v10.2309.03.00264 and Hexagon HxGN OnCall Dispatch Advantage (Mobile) v10.2402 are vulnerable to Cross Site Scripting (XSS) which allows a remote authenticated attacker with access to the Broadcast (Person) functionality to execute arbitrary code. |
| DASAN GPON ONU H660WM H660WMR210825 is susceptible to improper access control under its default settings. Attackers can exploit this vulnerability to gain unauthorized access to sensitive information and modify its configuration via the UPnP protocol WAN sides without any authentication. |
| A URL redirection in Pinokio v3.6.23 allows attackers to redirect victim users to attacker-controlled pages. |
| Keyoti SearchUnit prior to 9.0.0. is vulnerable to XML External Entity (XXE). An attacker who can force a vulnerable SearchUnit host into parsing maliciously crafted XML and/or DTD files can exfiltrate some files from the underlying operating system. |
| "Gunosy" App contains a vulnerability where sensitive information may be included in the application's outbound communication. If a user accesses a crafted URL, an attacker may obtain the JWT (JSON Web Token). |
| Missing Release of Resource after Effective Lifetime (CWE-772) in the Gallagher T-Series Reader allows an attacker with physical access to the reader to perform a limited denial of service when 125 kHz Card Technology is enabled.
This issue affects T-Series Readers: 9.20 prior to vCR9.20.250213a (distributed in 9.20.1827 (MR2)), 9.10 prior to vCR9.10.250213a (distributed in 9.10.2692(MR5)), 9.00 prior to vCR9.00.250619a (distributed in vEL9.00.3371 (MR7)), all versions of 8.90 and prior. |
| An issue was discovered on KuWFi GC111 devices (Hardware Version: CPE-LM321_V3.2, Software Version: GC111-GL-LM321_V3.0_20191211). They are vulnerable to unauthenticated /goform/goform_set_cmd_process requests. A crafted POST request, using the SSID parameter, allows remote attackers to execute arbitrary OS commands with root privileges. |
| An issue was discovered on KuWFi GC111 GC111-GL-LM321_V3.0_20191211 devices. The TELNET service is enabled by default and exposed over the WAN interface without authentication. |
| Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI. |
| When uploading organism or sequence data via the web interface,
GMOD Apollo
will unzip and inspect the files and will not check for path
traversal in supported archive types. |
| LabVantage before LV 8.8.0.13 HF6 allows local file inclusion. Authenticated users can retrieve arbitrary files from the environment via the objectname request parameter. |
| DPMAdirektPro 4.1.5 is vulnerable to DLL Hijacking. It happens by placing a malicious DLL in a directory (in the absence of a legitimate DLL), which is then loaded by the application instead of the legitimate DLL. This causes the malicious DLL to load with the same privileges as the application, thus causing a privilege escalation. |
| The ip (aka node-ip) package through 2.0.1 (in NPM) might allow SSRF because the IP address value 0 is improperly categorized as globally routable via isPublic. NOTE: this issue exists because of an incomplete fix for CVE-2024-29415. NOTE: in current versions of several applications, connection attempts to the IP address 0 (interpreted as 0.0.0.0) are blocked with error messages such as net::ERR_ADDRESS_INVALID. However, in some situations that depend on both application version and operating system, connection attempts to 0 and 0.0.0.0 are considered connection attempts to 127.0.0.1 (and, for this reason, a false value of isPublic would be preferable). |
| Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| Codemers KLIMS 1.6.DEV allows Python code injection. A user can provide Python code as an input value for a parameter or qualifier (such as for sorting), which will get executed on the server side. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| Hashview 0.8.1 allows account takeover via the password reset feature because SERVER_NAME is not configured and thus a reset depends on the Host HTTP header. |
| The ip (aka node-ip) package through 2.0.1 (in NPM) might allow SSRF because the IP address value 017700000001 is improperly categorized as globally routable via isPublic. NOTE: this issue exists because of an incomplete fix for CVE-2024-29415. |
| NVIDIA ConnectX contains a vulnerability in the management interface, where an attacker with local access could cause incorrect authorization to modify the configuration. A successful exploit of this vulnerability might lead to denial of service, escalation of privileges, information disclosure, and data tampering. |
| NVIDIA TensorRT-LLM for any platform contains a vulnerability in python executor where an attacker may cause a data validation issue by local access to the TRTLLM server. A successful exploit of this vulnerability may lead to code execution, information disclosure and data tampering. |