| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to
unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious
user, having physical access, sets the radio to the factory default mode. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of
confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the
product does not correctly initialize all data. |
| A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow. |
| Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an
attacker to execute unauthorized commands when a system’s default password credentials have not been
changed on first use. The default username is not displayed correctly in the WebHMI interface. |
| Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched. |
| Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927. |
| The BigFix SaaS's HTTP responses were missing some security headers. The absence of these headers weakens the application's client-side security posture, making it more vulnerable to common web attacks that these headers are designed to mitigate, such as Cross-Site Scripting (XSS), Clickjacking, and protocol downgrade attacks. |
| VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services.
Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.
Workarounds or Mitigation:
Versa recommends the following security controls:
1) Change default passwords to complex passwords
2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character
3) Passwords must be changed at least every 90 days
4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password.
5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps. |
| A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it. |
| Improper isolation in the Intel(R) Core(TM) Ultra Processor stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access. |
| Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials |
| Improper isolation of shared resources on System-on-a-chip (SOC) could a privileged attacker to tamper with the contents of the PSP reserved DRAM region potentially resulting in loss of confidentiality and integrity. |
| Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges. |
| Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product. |
| Budibase is an open-source low-code platform. Prior to version 3.33.4, a server-side request forgery (SSRF) vulnerability exists in Budibase's REST datasource connector. The platform's SSRF protection mechanism (IP blacklist) is rendered completely ineffective because the BLACKLIST_IPS environment variable is not set by default in any of the official deployment configurations. When this variable is empty, the blacklist function unconditionally returns false, allowing all requests through without restriction. This issue has been patched in version 3.33.4. |