Search Results (366284 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-47762 2 Backstage, Redhat 2 Backstage, Rhdh 2026-04-15 5.8 Medium
Backstage is an open framework for building developer portals. Configuration supplied through APP_CONFIG_* environment variables, for example APP_CONFIG_backend_listen_port=7007, where unexpectedly ignoring the visibility defined in configuration schema. This occurred even if the configuration schema specified that they should have backend or secret visibility. This was an intended feature of the APP_CONFIG_* way of supplying configuration, but now clearly goes against the expected behavior of the configuration system. This behavior leads to a risk of potentially exposing sensitive configuration details intended to remain private or restricted to backend processes. The issue has been resolved in version 0.3.75 of the @backstage/plugin-app-backend package. As a temporary measure, avoid supplying secrets using the APP_CONFIG_ configuration pattern. Consider alternative methods for setting secrets, such as the environment substitution available for Backstage configuration.
CVE-2024-51324 2026-04-15 3.8 Low
An issue in the BdApiUtil driver of Baidu Antivirus v5.2.3.116083 allows attackers to terminate arbitrary process via executing a BYOVD (Bring Your Own Vulnerable Driver) attack.
CVE-2024-52813 2026-04-15 4.3 Medium
matrix-rust-sdk is an implementation of a Matrix client-server library in Rust. Versions of the matrix-sdk-crypto Rust crate before 0.8.0 lack a dedicated mechanism to notify that a user's cryptographic identity has changed from a verified to an unverified one, which could cause client applications relying on the SDK to overlook such changes. matrix-sdk-crypto 0.8.0 adds a new VerificationLevel::VerificationViolation enum variant which indicates that a previously verified identity has been changed.
CVE-2024-53648 2026-04-15 6.8 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.
CVE-2024-53651 2026-04-15 4.6 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.
CVE-2024-54089 2026-04-15 7.5 High
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key. This could allow an attacker to guess or decrypt the password from the cyphertext.
CVE-2024-54090 2026-04-15 5.9 Medium
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function. This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state.
CVE-2024-54092 2026-04-15 9.8 Critical
A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.
CVE-2024-55354 2026-04-15 8.8 High
Lucee before 5.4.7.3 LTS and 6 before 6.1.1.118, when an attacker can place files on the server, is vulnerable to a protection mechanism failure that can let an attacker run code that would be expected to be blocked and access resources that would be expected to be protected.
CVE-2024-55969 2026-04-15 9.1 Critical
DocIO in Syncfusion Essential Studio for ASP.NET MVC before 27.1.55 throws XMLException during the resaving of a DOCX document with an external reference XML, aka I640714.
CVE-2024-55970 2026-04-15 7.5 High
File Manager in Syncfusion Essential Studio for ASP.NET MVC before 27.1.55 has a traversal issue that is related to the request parameter, aka I644734.
CVE-2024-58300 1 Siklu 1 Multihaul Tg Series 2026-04-15 N/A
Siklu MultiHaul TG series devices before version 2.0.0 contain an unauthenticated vulnerability that allows remote attackers to retrieve randomly generated credentials via a network request. Attackers can send a specific hex-encoded command to port 12777 to obtain username and password, enabling direct SSH access to the device.
CVE-2024-58290 1 Elements 1 Xhibiter Nft Marketplace 2026-04-15 N/A
Xhibiter NFT Marketplace 1.10.2 contains a SQL injection vulnerability in the collections endpoint that allows attackers to manipulate database queries through the 'id' parameter. Attackers can exploit boolean-based, time-based, and UNION-based SQL injection techniques to potentially extract or manipulate database information by sending crafted payloads to the collections page.
CVE-2024-58291 1 Flatboard 1 Flatboard 2026-04-15 N/A
Flatboard 3.2 contains a stored cross-site scripting vulnerability that allows authenticated administrators to inject malicious scripts in forum information fields. Attackers can insert JavaScript payloads that execute when other users view the forum, potentially stealing session cookies and executing client-side scripts.
CVE-2024-58302 1 Flarum 2 Flarum, Pretty Mail 2026-04-15 N/A
FoF Pretty Mail 1.1.2 contains a local file inclusion vulnerability that allows administrative users to include arbitrary server files in email templates. Attackers can exploit the template settings by inserting file inclusion payloads to read sensitive system files like /etc/passwd during email generation.
CVE-2024-58303 1 Flarum 2 Flarum, Pretty Mail 2026-04-15 N/A
FoF Pretty Mail 1.1.2 contains a server-side template injection vulnerability that allows administrative users to inject malicious code into email templates. Attackers can execute system commands by inserting crafted template expressions that trigger arbitrary code execution during email generation.
CVE-2024-58306 1 Hans Alshoff 1 Minalic 2026-04-15 N/A
minaliC 2.0.0 contains a denial of service vulnerability that allows remote attackers to crash the web server by sending oversized GET requests. Attackers can send crafted HTTP requests with excessive data to overwhelm the server and cause service interruption.
CVE-2024-58310 1 Apc 2 Apcupsd Firmware, Network Management Card 2026-04-15 N/A
APC Network Management Card 4 contains a path traversal vulnerability that allows unauthenticated attackers to access sensitive system files by manipulating URL parameters. Attackers can exploit directory traversal techniques to read critical system files like /etc/passwd by using encoded path traversal characters in HTTP requests.
CVE-2024-6098 2026-04-15 5.3 Medium
When performing an online tag generation to devices which communicate using the ControlLogix protocol, a machine-in-the-middle, or a device that is not configured correctly, could deliver a response leading to unrestricted or unregulated resource allocation. This could cause a denial-of-service condition and crash the Kepware application. By default, these functions are turned off, yet they remain accessible for users who recognize and require their advantages.
CVE-2024-6923 2 Python, Redhat 7 Cpython, Enterprise Linux, Rhel Aus and 4 more 2026-04-15 5.5 Medium
There is a MEDIUM severity vulnerability affecting CPython. The email module didn’t properly quote newlines for email headers when serializing an email message allowing for header injection when an email is serialized.