| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code. |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY). |
| An exploitable OS Command Injection vulnerability exists in the web application 'ping' functionality of Moxa AWK-3131A Wireless Access Points running firmware 1.1. Specially crafted web form input can cause an OS Command Injection resulting in complete compromise of the vulnerable device. An attacker can exploit this vulnerability remotely. |
| A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device. |
| An exploitable information disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point. Retrieving a series of URLs without authentication can reveal sensitive configuration and system information to an attacker. |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded. |
| An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. User is able to execute arbitrary OS commands on the server. |
| A Credentials Management issue was discovered in Moxa NPort W2150A versions prior to 1.11, and NPort W2250A versions prior to 1.11. The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic. |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted. |
| An exploitable information disclosure vulnerability exists in the Web Application functionality of the Moxa AWK-3131A wireless access point running firmware 1.1. Retrieving a specific URL without authentication can reveal sensitive information to an attacker. |
| An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption. |
| A Resource Exhaustion issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exhaust memory resources by sending a large amount of TCP SYN packets. |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext. |
| An exploitable null pointer dereference exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Any HTTP GET request not preceded by an '/' will cause a segmentation fault in the web server. An attacker can send any of a multitude of potentially unexpected HTTP get requests to trigger this vulnerability. |
| An Injection issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to inject packets that could potentially disrupt the availability of the device. |
| An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication. |
| An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. The Change Password functionality of the Web Application transmits the password in cleartext. An attacker capable of intercepting this traffic is able to obtain valid credentials. |
| UC-8100A-ME-T System Image: Versions v1.0 to v1.6, UC-2100 System Image: Versions v1.0 to v1.12, UC-2100-W System Image: Versions v1.0 to v 1.12, UC-3100 System Image: Versions v1.0 to v1.6, UC-5100 System Image: Versions v1.0 to v1.4, UC-8100 System Image: Versions v3.0 to v3.5, UC-8100-ME-T System Image: Versions v3.0 and v3.1, UC-8200 System Image: v1.0 to v1.5, AIG-300 System Image: v1.0 to v1.4, UC-8410A with Debian 9 System Image: Versions v4.0.2 and v4.1.2, UC-8580 with Debian 9 System Image: Versions v2.0 and v2.1, UC-8540 with Debian 9 System Image: Versions v2.0 and v2.1, and DA-662C-16-LX (GLB) System Image: Versions v1.0.2 to v1.1.2 of Moxa's ARM-based computers have an execution with unnecessary privileges vulnerability, which could allow an attacker with user-level privileges to gain root privileges. |
| Cradlepoint IBR600 NCOS versions 6.5.0.160bc2e and prior are vulnerable
to shell escape, which enables local attackers with non-superuser
credentials to gain full, unrestrictive shell access which may allow an
attacker to execute arbitrary code.
|
| Two buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O Series firmware version 2.2 or earlier may allow a remote attacker to cause a denial-of-service condition. |