| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks. |
| Improper control of framework service permissions with possibility of some sensitive device information leakage. |
| Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information. |
| Intelbras Router RF 301K firmware version 1.1.2 contains an authentication bypass vulnerability that allows unauthenticated attackers to download router configuration files. Attackers can send a specific HTTP GET request to /cgi-bin/DownloadCfg/RouterCfm.cfg to retrieve sensitive router configuration without authentication. |
| The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device. |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint. |
| COMMAX Smart Home System is a smart IoT home solution that allows an unauthenticated attacker to disclose RTSP credentials in plain-text by exploiting the /overview.asp endpoint. Attackers can access sensitive information, including login credentials and DVR settings, by submitting a GET request to this endpoint. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates. |
| When configuring Arc (e.g. during the first setup), a local web interface is provided to ease the configuration process. Such web interface lacks authentication and may thus be abused by a local attacker or malware running on the machine itself.
A malicious local user or process, during a window of opportunity when the local web interface is active, may be able to extract sensitive information or change Arc's configuration. This could also lead to arbitrary code execution if a malicious update package is installed. |
| Anheng Mingyu Operation and Maintenance Audit and Risk Control System up to 2023-08-10 contains a server-side request forgery (SSRF) vulnerability in the xmlrpc.sock handler. The product accepts specially crafted XML-RPC requests that can be used to instruct the server to connect to internal unix socket RPC endpoints and perform privileged XML-RPC methods. An attacker able to send such requests can invoke administrative RPC methods via the unix socket interface to create arbitrary user accounts on the system, resulting in account creation and potential takeover of the bastion host. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:17.837319 UTC. |
| Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| Nedap Librix Ecoreader
is missing authentication for critical functions that could allow an
unauthenticated attacker to potentially execute malicious code. |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) versions prior to 1.3.4 contain an authentication bypass in the NVMS-9000 control protocol. By sending a single crafted TCP payload to an exposed NVMS-9000 control port, an unauthenticated remote attacker can invoke privileged administrative query commands without valid credentials. Successful exploitation discloses sensitive information including administrator usernames and passwords in cleartext, network and service configuration, and other device details via commands such as queryBasicCfg, queryUserList, queryEmailCfg, queryPPPoECfg, and queryFTPCfg. |
| Improper authentication vulnerability in exists in multiple printers and scanners which implement Web Based Management provided by BROTHER INDUSTRIES, LTD. If this vulnerability is exploited, a network-adjacent user who can access the product may impersonate an administrative user. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| An unauthenticated attacker can reset the board and stop transmitter
operations by sending a specially-crafted GET request to the command.cgi
gateway, resulting in a denial-of-service scenario. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |