Search Results (2492 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-0280 1 Hcltech 1 Compass 2026-04-15 7.5 High
A security vulnerability in HCL Compass can allow attacker to gain unauthorized database access.
CVE-2024-12650 2026-04-15 5.4 Medium
An attacker with low privileges can manipulate the requested memory size, causing the application to use an invalid memory area. This could lead to a crash of the application but it does not affected other applications.
CVE-2022-38695 2026-04-15 7.8 High
In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2025-2555 2026-04-15 2.9 Low
A vulnerability classified as problematic has been found in Audi Universal Traffic Recorder App 2.0. Affected is an unknown function of the component FTP Credentials. The manipulation leads to use of hard-coded password. Attacking locally is a requirement. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers.
CVE-2025-32802 1 Redhat 1 Enterprise Linux 2026-04-15 6.1 Medium
Kea configuration and API directives can be used to overwrite arbitrary files, subject to permissions granted to Kea. Many common configurations run Kea as root, leave the API entry points unsecured by default, and/or place the control sockets in insecure paths. This issue affects Kea versions 2.4.0 through 2.4.1, 2.6.0 through 2.6.2, and 2.7.0 through 2.7.8.
CVE-2025-50505 1 Clash-verge 1 Clash-verge 2026-04-15 7.8 High
Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation.
CVE-2025-2556 2026-04-15 4.3 Medium
A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers.
CVE-2025-1394 1 Silabs 1 Emberznet 2026-04-15 N/A
The Ember ZNet stack’s packet buffer manager may read out of bound memory leading to an assert, causing a Denial of Service (DoS).
CVE-2024-4425 2026-04-15 5.4 Medium
The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
CVE-2018-25130 2026-04-15 6.2 Medium
Beward Intercom 2.3.1 contains a credentials disclosure vulnerability that allows local attackers to access plain-text authentication credentials stored in an unencrypted database file. Attackers can read the BEWARD.INTERCOM.FDB file to extract usernames and passwords, enabling unauthorized access to IP cameras and door stations.
CVE-2025-8730 1 Belkin 2 F9k1009, F9k1010 2026-04-15 9.8 Critical
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-3364 1 Hgiga 1 Powerstation 2026-04-15 6.7 Medium
The SSH service of PowerStation from HGiga has a Chroot Escape vulnerability, allowing attackers with root privileges to bypass chroot restrictions and access the entire file system.
CVE-2025-54754 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8 High
An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available software. This password can then be used to decrypt sensitive network traffic, affecting the Cognex device.
CVE-2022-26388 2026-04-15 6.4 Medium
A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-42496 2026-04-15 N/A
Smart-tab Android app installed April 2023 or earlier contains an issue with plaintext storage of a password. If this vulnerability is exploited, an attacker with physical access to the device may retrieve the credential information and spoof the device to access the related external service.
CVE-2025-42958 1 Sap 2 Netweaver, Sap Netweaver 2026-04-15 9.1 Critical
Due to a missing authentication check in the SAP NetWeaver application on IBM i-series, the application allows high privileged unauthorized users to read, modify, or delete sensitive information, as well as access administrative or privileged functionalities. This results in a high impact on the confidentiality, integrity, and availability of the application.
CVE-2025-7080 1 Done-0 1 Jank 2026-04-15 3.7 Low
A vulnerability, which was classified as problematic, was found in Done-0 Jank up to 322caebbad10568460364b9667aa62c3080bfc17. Affected is an unknown function of the file internal/utils/jwt_utils.go of the component JWT Token Handler. The manipulation of the argument accessSecret/refreshSecret with the input jank-blog-secret/jank-blog-refresh-secret leads to use of hard-coded password. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2024-42197 1 Hcltech 1 Workload Scheduler 2026-04-15 5.5 Medium
HCL Workload Scheduler stores user credentials in plain text which can be read by a local user.